THERMOREGULATION
FLUE SYSTEMS
OPTIONS
 
Hybrid Systems
Heat Pumps
Thermal Solar System
Solar System Ready
Light Commercial
Condensing Boilers
Traditional Boilers
Complete range
Wall-hung
Floor-standing
Complete range
Hybrid mono-phase
Split mono-phase
Mono-phase
Three-phase
Complete range
Individual components
Complete range
Floor-standing
Complete range
Wall-hung
Floor-standing
Modular thermal block
Counter units
Complete range
Top Tech wall-hung
Hi-Tech wall-hung
Wall-hung and floor-standing with built-in storage tank
Complete range
Wall-hung
Wall-hung for outdoor installation
Wall-hung with built-in storage tank
Solar probe kit       Code 3.021452
Available for VICTRIX and MAIOR EOLO
GSM telephonic control       Code 3.017182

For buildings not equipped with telephone network. Available for all Immergas models.

DOMINUS interface kit       Code 3.026273
Available for: VICTRIX TT range and VICTRIX EXA.
Control box for pumps and zone       Code 3.011668
Maximum three zones.
Available for: all Superior models and VICTRIX TT, VICTRIX Zeus, HERCULES, ZEUS kW, AVIO kW, MAIOR EOLO and NIKE Mini 28 kW Special.
Storage tank NTC probe       Code 3.019375

Allows to check the DHW temperature of a commercial Storage Tank Unit with the Immergas boiler <35 kW.
Provided as per standard on all Storage Tank Units in the catalogue.

CARV2 (weekly thermostat and modulating remote control)       Code 3.021395

Available for all models.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

*as standard

Relay board kit       Code 3.015350
Allows interface between zone valves and CAR or Super CAR, to send an alarm signal, to manage external pump etc.
Available for: all Superior models and VICTRIX, VICTRIX TT, VICTRIX X, VICTRIX R, HERCULES, MAIOR EOLO and EOLO Extra kW.
CARV2 WIRELESS (radio wave weekly thermostat and modulating remote control)       Code 3.021623
Available for: VICTRIX, VICTRIX TT, VICTRIX MAIOR TT, VICTRIX X, MAIOR EOLO, NIKE Mini 28 kW Special, MINI NIKE/EOLO, MINI NIKE/EOLO X and NIKE/EOLO Star.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

* as standard

Relay board kit       Code 3.017331
Allows interface between zone valves and CAR or Super CAR.
Available for VICTRIX Zeus only.
Safety thermostat kit       Cod. 3.019229

For VICTRIX Superior TOP/X, VICTRIX, VICTRIX X and VICTRIX R.

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)       Code 3.021624

Available for all models.

Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%

* as standard

Mini CRD (Mini weekly thermostat and modulating remote control)       Code 3.020167
Available for: VICTRIX TT, VICTRIX EXA, NIKE Mini 28 kW Special, MINI NIKE/EOLO, MINI NIKE/EOLO X and NIKE/EOLO Star.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

* as standard

CRONO 7 (weekly digital chronothermostat)       Code 3.021622

Available for all models.

Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* as standard

Telephonic control       Code 3.013305

For buildings equipped with telephone network. Available for all Immergas models.

Super CAR (weekly thermostat and modulating remote control)       Code 3.016577
Available for: All Superior models and VICTRIX Zeus, HERCULES, ZEUS kW, AVIO kW, NIKE Mini 28 kW Special.

Class of device V* or VI
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

* as standard

External probe       Code 3.014083
Allows at the boiler to functioning at a variable temperature according to the climatic conditions. Available for all models, except NIKE/EOLO Star.

Class of device II*
Contribution to the environmental heating seasonal energy efficiency 2%*

* as standard

Safety thermostat kit       Code 3.019869

For HERCULES Condensing and HERCULES Solar.

Room thermostat       Code 3.012287
Simple thermostat for the manual regulation of the temperature. Available for all models.
Temperature/humidity active sensor kit       Code 3.021524

To be used with radiant systems that also work in cooling mode.

Class of device V or VI*
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%*

* as standard

2 relays board kit       Code 3.026302

To be installed for the deumidifiers management without in absence of system manager kit.

Dedicated to MAGIS PRO ErP and MAGIS COMBO.

 

 

System controller       Code 3.021522
Class of device VI* or VIII
Contribution to the environmental heating seasonal energy efficiency 4%* or 5%
 
* as standard
Zone controller       Code 3.021523
Room hygrostat       Code 3.023302

To be used with radiant systems that also work in cooling mode.

Remote control kit       Code 3.023364
Class of device V or VI*
Contribution to the environmental heating seasonal energy efficiency 3% or 4%*
 
* as standard
System controller expansion kit       Code 3.021547

Da utilizzare in presenza di sistemi integrati, solo in abbinamento al gestore di sistema (cod. 3.021522). Permette di gestire ausiliari quali: pompa di circolazione, valvola miscelatrice, deumidificatore, pompa di ricircolo, valvole 3 vie deviatrici per riscaldamento/raffrescamento. Da alimentare in bassa tensione (24 Vac).

Low temperature safety kit       Cod. 3.013794

Dedicated to GAUDIUM SOLAR 2 zones/PLUS ErP and DIM 2/3 zones ErP or to kit code no. 3.021527 and 3.021528 (to be installed on the delivery manifold).

 

 

 

EMR 12 VDC relay kit       Code 3.023945
SSR 6 VDC relay kit       Code 3.023946

To be used for electric integration.

Solar central unit kit      Code 3.019097

For UB Inox 120-2 and UB Inox 200-2.
Ideal for solar thermal systems with exclusive integration of domestic hot water, thanks to the probe supplied as per standard, it controls the circulation pump based on the real availability of solar energy and the temperature of the solar storage tank.

PRO solar central unit      Cod. 3.019519
Advanced central unit, capable of managing special systems (such as two sets of collectors on double-pitched roofs, heating systems integration, heating integration for swimming pools etc.). Supplied as per standard with four probes, to be able to control two different ΔT based on the type of system required.
It is supplied as per standard in combined solar packs for heating and domestic hot water integration.

Zone manager kit       Code 3.015264

Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone, and allow remote control of the cascade and zone regulator.
Kit sonda esterna (for single installation)       Code 3.015266

Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

System delivery probe kit for the boiler VICTRIX PRO       Code 3.024245

Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

Solar collector temperature probe kit for UB Inox Solar 200-2, HERCULES Solar      Code 1.028812
As per standard with these products.
Flow probe       Code 3.015267

Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.

External probe (for installation in battery)       Code 3.024511

Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function

Data expansion kit for 125 users       Code 3.023035
To be installed in combination with a data concentrator for 60 users.
Wall box kit for cascade and zone regulator       Code 3.015265

If the cascade and zone regolator is not install inside an electrical box.

Modulating room thermostat       Code 3.015245

Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.

Tele-management kit       Code 3.024244

Can be combined exclusively with the cascade and zone regulator for connection to an ethernet network or via router/modem to an ADSL line for connection to a remote system.

Remote control for single VICTRIX PRO       Code 3.020358
This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.
Cascade and zone regulator kit       Code 3.015244
ON-OFF adjustment, modulation and malfunctions of the VICTRIX PRO in cascade (max 8). It can manage any climatic zone regulators in the system (max 3 plus 1 dedicated to the hot tap water circuit).
Cascade regulator ARES Tec      Cod. 3.023667
Zone manager ARES Tec      Code 3.023665
Wall box kit for cascade regulator ARES Tec       Code 3.023668
Interface kit for modem connection and tele-management ARES Tec       Code 3.023669
Free downloading online software
Zones expansion kit ARES Tec       Code 3.023664
Flow probe kit ARES Tec       Cod. 3.023700
Data expansion kit for 250 users       Code 3.023036
To be installed in combination with a data concentrator for 60 users.
Modulating room themostat ARES Tec       Code 3.023666
Hybrid Systems
Heat Pumps
Solar System Ready
Light Commercial
Condensing Boilers
Traditional Boilers
Instantaneous Water Heaters
Complete range
Wall-hung
Floor-standing
Complete range
Hybrid mono-phase
Water heater
Complete range
Floor-standing
Complete range
Wall-hung
Floor-standing
Modular thermal block
Complete range
Top Tech wall-hung
Hi-Tech wall-hung
Wall-hung and floor-standing with built-in storage tank
Complete range
Wall-hung
Wall-hung for outdoor installation
Wall-hung with built-in storage tank
Complete range
Sealed chamber
Heat pump water heaters

Chimney hole closing panel       Code 3.012008

Hole closing panel, inspection door and grommet for ducting system.
For condensing boilers < 35 kW.

4 extension pipes Ø 80 kit 0,5 m long       Code 3.014642

For condensing boilers < 35 kW.

4 extension pipes Ø 80 kit 1 m long       Code 3.012088

For condensing boilers < 35 kW.

Ø 125 adapter kit for C9 ducting system       Code 3.022033

For direct air intake from an existing chimney with green series ducting systems. The kit must combined with Ø 80/125 flue discharge kits according to the condensing boiler installation.
For condensing boilers.

Extension pipe kit Ø 60/100 0,5 m long       Code 3.014643

For condensing boiler < 35 kW.

Anti-wind vertical terminal kit Ø 80       Code 3.021721

For condensign boiler < 35 kW.

Flanged stub-pipe + bend + extension pipe Ø 80 for flue discharge       Code 3.016365

For condensing boilers < 35 kW.

Twin pipes complete kit Ø 80/80       Code 3.012002

For condensing boiler < 35 kW.

Components support kit Ø 50 mm for flexible ducting system       Code 3.027355

Flexible chimney ducting system for condensing boilers.

Flanged stub-pipe kit Ø 80       Code 3.012087

For condensing boilers < 35 kW.

Flanged stub-pipe Ø 80 for flue discharge       Code 3.016364

For condensing boilers < 35 kW.

Horizontal concentric complete kit Ø 60/100 with swivel terminal       Code 3.024267
Max lenght 9,9 m.
For condensing boiler < 35 kW except HP models.

Vertical outlet kit for ducting system Ø 60       Code 3.012112

Vertical concentric exhaust flue terminal Ø 60 and chimney closing panel.
For condensign boilers < 35 kW.

Flange Ø 60/100 coupling Ø 80/125 adapter kit       Code 3.022990

To be used with the concentric kits.
For condensing boiler < 35 kW.

Ø 100 adapter kit for C9 ducting system       Code 3.022032

For direct air intake from an existing chimney with green series duct systems.
For condensing boilers < 35 kW.
CARV2 (Comando Amico Remoto modulante)

90° bend Ø 60 for ducting system       Code 3.013870

For condensing boilers < 35 kW.

CARV2 (Comando Amico Remoto modulante)

Horizontal outlet terminal Ø 80       Code 3.016363

For condensing boiler < 35 kW.

Terminal vertical outlet kit Ø 80       Code 3.015256

For condensing boiler < 35 kW.

Push-fitting extension pipes kit 1 m for ducting system Ø 60       Code 3.012144

4 extension pipes Ø 60 2 m long.
For condensing boilers < 35 kW.

Flexible ducting kit Ø 80 mm       Code 3.014170

L=12 m + 4 centering spacers.
For condensing boilers.

4 x 90° bends Ø 80 kit       Code 3.012091

For condensing boilers < 35 kW.

Flanged stub-pipe kit Ø 60/100       Code 3.012086

For condensing boiler < 35 kW.

45° bend Ø 80 kit       Code 3.012092

For condensing boilers < 35 kW.

 Ø 80 "T-shaped" terminal kit  Ø 80 (C5) for flexible ducting system       Code 3.027356

Flexible chimney ducting system for condensing boilers.

Flexible hose kit Ø 50 mm L. 10 m       Code 3.027354

Flexible chimney ducting system for condensing boilers.

Vertical outlet kit Ø 80/125 for flexible ducting system       Code 3.014174

For condensing boilers.

45° bend Ø 60/100 kit       Code 3.012095

For condensing boiler < 35 kW.

Kit support components for flexible ducting system       Code 3.014171

For condensing boilers.

CARV2 (Comando Amico Remoto modulante)

Push-fitting extension pipes kit 2 m for ducting system Ø 60       Code 3.013869

1 extension pipe Ø 60 2 m long.
For condensing boilers < 35 kW.

90° bend Ø 60/100 kit       Code 3.012093

For condensing boiler < 35 kW.

Push-fitting extension pipes kit 1 m for ducting system Ø 60       Code 3.012144

4 extension pipes Ø 60 2 m long.
For condensing boilers < 35 kW.
CARV2 (Comando Amico Remoto modulante)

1 extension pipe Ø 80 2 m long       Code 3.016837

For condensing boilers < 35 kW.

Adapter F/F       Code 3.014172

For flexible ducting system, Ø 80.
For condensing boilers.

Valley kit for flexible ducting system       Code 3.014173

For condensing boilers.

90° bend terminal kit  Ø 50 (C5) for flexible ducting system       Code 3.027357

Flexible chimney ducting system for condensing boilers.

CARV2 (Comando Amico Remoto modulante)

Push-fitting extension pipes kit 2 m for ducting system Ø 60       Code 3.013869

1 extension pipe Ø 60 2 m long.
For condensing boilers < 35 kW.

Vertical concentric kit Ø 80/125       Code 3.015243

For VICTRIX PRO.

Concentric horizontal complete kit Ø 60/100       Code 3.012000

Max lenght 12,9 m.
For condensing boiler < 35 kW.

Concentric vertical complete kit Ø 60/100 (black colour)       Code 3.018501
For condensing boiler < 35 kW.

Flexible/flexible adapter kit for flexible ducting system Ø 50       Code 3.027359

Flexible chimney ducting system for condensing boilers.

90° bend Ø 60/100 kit with inspection hole       Code 3.016174
For condensing boiler < 35 kW.
Horizontal concentric complete kit Ø 60/100 with swivel terminal       Code 3.024267
Max lenght 9,9 m.
For condensing boiler < 35 kW except HP models.

Vertical terminal kit  Ø 80/125 for flexible ducting system Ø 50 (C5+C9)       Code 3.027358

Flexible chimney ducting system for condensing boilers.

Support bend kit for ducting system Ø 60       Code 3.012153

Support bend Ø 60, bend locking collar, clamp,
reduction Ø 80 - Ø 60.
For condensing boilers < 35 kW.
Concentric vertical complete kit Ø 60/100 (red ocher colour)       Code 3.016833

Lunghezza 956 mm, estensione massima 12,9 metri.
Utilizzabile solo per caldaie a condensazione < 35 kW.

Horizontal concentric kit Ø 80/125       Code 3.015242

For VICTRIX PRO.

Hanging bracket kit       Code 3.011600

Adjustable support chimney hanging bracket, for ducting system.
For traditional and condensing boilers < 35 kW.

HERCULES Condensing B22 - B23 terminal kit        Code 3.020004

Horizontal concentric complete kit Ø 60/100 Short       Code 3.024598

Max lenght 11,9 m.
For condensing boiler < 35 kW.

Extension pipe kit Ø 60/100 1 m long       Code 3.012089

For condensing boiler < 35 kW.

CARV2 (Comando Amico Remoto modulante)

Spacer pipe clamp kit for ducting system Ø 60       Code 3.012146

3 spacer pipe clamps Ø 60.
For condensing boilers < 35 kW.
CARV2 (Comando Amico Remoto modulante)

Pipe clamp kit for ducting system Ø 60       Code 3.012145

5 pipe clamps Ø 60.
For condensing boilers < 35 kW.

Concentric horizontal outlet Ø 60/100       Code 3.016836

45° bend Ø 80/125      CodE 3.010952

For traditional boilers.

Flanged stub-pipes Ø 80      Code 3.011570

For traditional boilers.

90° bend Ø 80 with inspection hole       Code 3.016175
Flue components for traditional boilers and water heaters.

Flanged stub-pipe Ø 60/100 vertical outlet      Code 3.011141

For traditional boilers.

90° bend Ø 60/100 with inspection hole       Code 3.016172
Flue components for traditional boilers and water heaters.
Female/female 90° bend Ø 80       Code 3.011571
Flue components for traditional boilers and water heaters.

Wind-stop outlet      Code 3.011488

For traditional boilers, Ø 80.

Flanged bend Ø 60/100       Code 3.011139
Flue components for traditional boilers and water heaters.
90° bend Ø 80/125 with inspection hole       Code 3.016171
Flue components for traditional boilers and water heaters.
5 pipe clamps kit       Code 3.011585

For traditional boilers, Ø 80 mm ducting system.

1 extension pipe Ø 80/125 0,5 m long      Code 3.011157

For traditional boilers.

Complete terminal kit       Code 3.011582

For traditional boilers, Ø 80 mm ducting system.

1 extension pipe Ø 60/100 2 m long       Code 3.010739

For traditional boilers.

Insulated twin pipes complete kit Ø 80/80       Code 3.010233

For traditional boilers.

45° bend Ø 80 kit      Code 3.010956

For traditional boilers.

4 x 90° bend Ø 80 kit      Code 3.010955

For traditional boilers.

1 extension pipe Ø 80/125 2 m long      Code 3.010946

For traditional boilers.

Horizontal outlet Ø 60/100       Code 3.011572

For traditional boilers.

Insulated 45° bend Ø 80 kit      Code 3.010954

For traditional boilers.

1 extension pipe Ø 80/125 1 m long      Code 3.010945

For traditional boilers.

Support bend kit       Code 3.012007

For traditional boilers, Ø 80 mm ducting system.

Flue outlet wind-stop grate Ø 80      Code 3.010962

For traditional boilers.

Insulated 90° bend Ø 80 kit      Code 3.010953

For traditional boilers.

Female/female stub-pipe Ø 80      Code 3.012714

For traditional boilers.

Concentric vertical complete kit Ø 80/125       Code 3.010352

For traditional boilers.

3 spacer pipe clamps kit       Code 3.011586

For traditional boilers, Ø 80 mm ducting system.

Twin pipes complete kit Ø 80/80       Code 3.010351

For traditional boilers.

"T" connector kit       Code 3.011595

For traditional boilers, Ø 80 mm ducting system.

"T" coupling seal kit with condensate trap       Code 3.011961

For traditional boilers, Ø 80 mm ducting system.

Kit comprised of "T" fitting, aluminum draining cap       Code 3.011601
The kit is completed with chimney closing panel for inspection, chimney inspection door and grommet Ø 16.
For traditional boilers.

Concentric horizontal complete kit Ø 80/125       Code 3.010526

For traditional boilers.

Chimney hole closing panel       Code 3.012008

For traditional boilers, Ø 80 mm ducting system.

Concentric vertical outlet Ø 60/100 (red ocher color)       Code 3.015631

To be combined with the flanged stub-pipe for vertical outlet (code 3.011141).
For traditional boilers.

Vertical flue outlet for twin pipes Ø 80       Code 3.010963

For traditional boilers.

1 insulated extension pipe Ø 80 1 m long       Code 3.010947

For traditional boilers.

Adapter Ø 60/100 - 80/125      Code 3.010957

For traditional boilers.

1 extension pipe Ø 60/100 1 m long       Code 3.018277
Flue components for traditional boilers and water heaters.
4 extension pipes Ø 80 1 m long       Code 3.011583

For traditional boilers, Ø 80 mm ducting system.

class="MsoNormal">1 extension pipe Ø 80 2 m long       Code 3.011167

For traditional boilers.

90° bend Ø 60/100       Code 3.018279
Flue components for traditional boilers and water heaters.
K1 extension pipe Ø 80 2 m long       Code 3.011584

For traditional boilers, Ø 80 mm ducting system.

1 extension pipe Ø 60/100 0,5 m long       Code 3.018278
Flue components for traditional boilers and water heaters.
Concentric horizontal complete kit Ø 60/100       Code 3.017736
Flue components for traditional boilers and water heaters.

4 extension pipes Ø 80 1 m long       Code 3.010741

For traditional boilers.

1 extension pipe Ø 60/100 0,3 m long with inspection hole       Code 3.014418
Flue components for traditional boilers and water heaters.

90° bend Ø 80/125      Code 3.010951

For traditional boilers.

1 insulated extension pipe Ø 80 2 m long       Code 3.010948

For traditional boilers.

Condense tank kit Ø 80      Code 3.012009

For traditional boilers.

4 extension pipes Ø 80 0,5 m long       Code 3.011491

For traditional boilers.

45° bend Ø 60/100      Code 3.010950

For traditional boilers.

Condensate siphon kit       Code 3.011599

For traditional boilers, Ø 80 mm ducting system.

Condense tank kit Ø 60/100       Code 3.016173
Flue components for traditional boilers and water heaters.

Condense tank kit Ø 80/125      Code 3.010960

For traditional boilers.

Concentric horizontal complete kit Ø 60/100 STAR       Code 3.014147

For traditional boilers.

Concentric horizontal anti-freeze complete kit Ø 60/100       Code 3.018210
Flue components for traditional boilers and water heaters.
Extension pipe Ø 160 kit 0,5 m long for flue manifold       Code 3.024659
For installations in central heating systems with VICTRIX PRO and for RAPAX.
87° bend kit Ø 160 for flue manifold       Code 3.024517
For installations in central heating systems with VICTRIX PRO and for RAPAX.
Inlet/exhaust pipes insulation kit for RAPAX V2       Code 3.027545

For RAPAX V2, heat pump water heater.
 

No. 2 45° bend kit Ø 160 for flue manifold       Code 3.024518

For installations in central heating systems with VICTRIX PRO and for RAPAX.

Duct adapter Ø 160       Code 3.025232

For RAPAX V2, heat pump water heater.
Using this kit you can match these kits:
- Extension pipe kit Ø 160 0,5 m long – code 3.024659
- Extension pipe kit Ø 160 1 m long – code 3.024516
- 87° bend kit Ø 160 - code 3.024517
- 2 x 45° bend kit Ø 160 - code 3.024518

Extension pipe Ø 200 kit 0,5 m long for flue manifold       Code 3.024663
For installations in central heating systems with VICTRIX PRO.  
Additional exhaust manifold kit Ø 250 with flue lock for 5 VICTRIX PRO 100/120       Cod. 3.024667

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.

Exhaust manifold kit 2 VICTRIX PRO 80/100/120 Ø 200 with flue lock       Code 3.024281

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.

Additional exhaust manifold kit Ø 250 with flue lock for 4 VICTRIX PRO 100/120       Code 3.024666

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.

Additional exhaust manifold kit VICTRIX PRO 35/55 Ø 160 with flue lock       Code 3.024280

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.

87° bend kit Ø 250 for flue manifold       Code 3.024670
For installations in central heating systems with VICTRIX PRO.
Extension pipe Ø 250 kit 1 m long for flue manifold       Code 3.024668

For installations in central heating systems with VICTRIX PRO.

No. 2 45° bend kit Ø 200 for flue manifold       Code 3.024664

For installations in central heating systems with VICTRIX PRO.

Extension pipe Ø 200 kit 1 m long for flue manifold       Code 3.024662
For installations in central heating systems with VICTRIX PRO.
Additional exhaust manifold kit VICTRIX PRO 80/100/120 Ø 200 with flue lock       Code 3.024282

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.

Supporting kit for side flue discharge ARES Tec       Code 3.023675
All models.
Rear flue discharge kit for ARES Tec 250/350 kW       Code 3.023674
In comparison to the standard versions, the ARES Tec 150/350 models can be installed with a flue exhaust on the back, using appropriate optional kits.

Exhaust manifold kit 2 VICTRIX PRO 35/55 Ø 160 with flue lock       Code 3.024279

Cascade installation - "Green Series" exhaust manifolds.
With installations in central heating systems, using up to 5 units in the battery, in configuration open chamber fan assisted, Immergas supplies special exhaust manifolds in PP equipped with flue lock (mechanical shutters), to prevent backflow of combustion products through the other non-functioning boilers.
The system is modular: there is an exhaust manifold kit for two boilers and one for additional boilers.
Rear flue discharge kit for ARES Tec 150/200 kW       Code 3.023701
In comparison to the standard versions, the ARES Tec 150/350 models can be installed with a flue exhaust on the back, using appropriate optional kits.

Horizontal kit Ø 80 (to discharge in the chimney)       Code 3.015254

For VICTRIX PRO.

No. 2 45° bend kit Ø 250 for flue manifold       Code 3.024669

For installations in central heating systems with VICTRIX PRO.

Terminal vertical outlet outdoor kit Ø 80       Code 3.024295

For VICTRIX PRO.

Terminal horizontal outlet kit Ø 80 (to discharge horizontally)       Code 3.015255

For VICTRIX PRO.

Hybrid Systems
Heat Pumps
Thermal Solar System
Solar System Ready
Light Commercial
Condensing Boilers
Traditional Boilers
Instantaneous Water Heaters
Complete range
Wall-hung
Floor-standing
Complete range
Hybrid mono-phase
Split mono-phase
Mono-phase
Three-phase
Water heater
Complete range
Pump-circulated packs for DHW
Combined pump-circulated packs for heating and DHW
Individual components
Packs with natural circulation for DHW
Complete range
Floor-standing
Complete range
Wall-hung
Floor-standing
Modular thermal block
Counter units
Complete range
Top Tech wall-hung
Hi-Tech wall-hung
Wall-hung and floor-standing with built-in storage tank
Complete range
Wall-hung
Wall-hung for outdoor installation
Wall-hung with built-in storage tank
Complete range
Open chamber
Sealed chamber
Heat pump water heaters
-15°C anti-freeze protection for CAESAR 14 3 E and Super CAESAR 17 3 E       Code 3.014113
1 litre bottle of glycol       Code 1.028473
To be mixed with water according to the minimum outside temperature.
12 litre system expansion vessel kit     Code 3.011679
18 litre expansion vessel kit        Code 3.019131
Including metal clamp and wall fixing bracket.
The expansion vessel must be dimensioned according to the content of the solar circuit fluid and the stagnation temperature of the collectors.
1"¼ thermostatic mixing valve kit        Code 3.020322
The kit includes:
1 thermostatic mixing valve with a 42 °C - 60 °C adjustment range and maximum inlet temperature of 85 °C.
Equipped with thermometer
2 brackets kit for slates/tiles for CP4 XL/M Flat-Plate Collector        Code 3.022680
The kit includes: 2 brackets, 1 fixing clamp with hole, 1 mounting template (to be removed after installation).
2 brackets kit for slates/tiles for CSV 14 Vacuum Collector        Code 3.022700
These systems allow installing vacuum collectors level on sloped roofs. Depending on the roof-type, appropriate screws/plugs must be provided to ensure a correct fixing.
The kit includes: 2 brackets, 1 fixing upright and 2 collector side fixing brackets.
2 high temperature zones kit for HERCULES SOLAR 26 ErP, HERCULES CONDENSING ErP        Code 3.025485

Modulating low consumption pumps.

2 litres additional expansion vessel       Code 3.017514
Available for: VICTRIX, VICTRIX X.
2 litres additional expansion vessel       Code 3.018433
Available for: ZEUS kW, ZEUS Superior kW, VICTRIX Zeus Superior kW, AVIO kW, VICTRIX Zeus, VICTRIX Superior TOP/X, MAIOR EOLO, MINI EOLO/NIKE and MINI EOLO/NIKE X.
2 low temperature zones kit for HERCULES SOLAR 26 ErP, HERCULES CONDENSING ErP       Code 3.025487

Modulating low consumption pumps.

2 plug kit for CP4 XL/M Flat-Plate Collector        Code 3.020364
The kit includes: 2 mechanical sealing plugs to close fittings not used by CP4 XL/M Flat-Plate Collector.

 
2 zones kit with motorized valves MAGIS VICTRIX     Code 3.023769
Dimensions (H x W x P) 220 x 350 x 230 mm.
24 litre expansion vessel kit       Code 3.019138
Including metal clamp and wall fixing bracket.
The expansion vessel must be dimensioned according to the content of the solar circuit fluid and the stagnation temperature of the collectors.
3 kW integration electric resistance kit     Cod. 3.026300

 

to be installed for central heating systems with MAGIS PRO ErP in stand-alone configuration (kit to be placed inside hydronic unit).

230 or 400 Vac power supply required.

3-way valve return temperature raising kit       Code 3.020632
For DOMESTIC SOL TOP.
35 litre expansion vessel kit        Code 3.019135
Including wall fixing bracket.
The expansion vessel must be dimensioned according to the content of the solar circuit fluid and the stagnation temperature of the collectors.
4 brackets kit for slates/tiles for CP4 XL/M Flat-Plate Collector        Code 3.022678
The kit includes: 4 brackets, 2 collector side fixing brackets.
It allows to fix the collector frame onto sloped roofs without drilling the tiles (for 1 collector).
4 brackets kit for slates/tiles to be drilled for CP4 XL/M Flat-Plate Collector        Code 3.019105
The kit includes: 4 brackets.
It allows to fix the collector frame onto sloped roofs.
Always add the fixing element kit code 3.022922.
4 brackets kit for slates/tiles to fix directly on roof for NATURAL SOL       Code 3.019236
It allows to fix the collector frame directly onto sloped roofs without drilling the tiles.
4 "L"-shaped brackets kit for slates/tiles on smooth roofs for CP4 XL/M Flat-Plate Collector        Code 3.022776
The kit includes: 4 brackets.
It allows to fix the selector frame onto smooth roofs (for 1 collector). Always add the fixing element kit code 3.022922.
80 litre expansion vessel kit        Code 3.019139
With support for placing on the floor.
The expansion vessel must be dimensioned according to the content of the solar circuit fluid and the stagnation temperature of the collectors.
90° gas valve for water heater    Code 3.014145
Additional 2 kW electric resistance kit for INOXSTOR 200/300/500 and UB 550/750     Code 3.020861
Additional 5 kW electric resistance kit for UB 1000/1500 and UB 750     Code 3.020862
Additional low temperature zone kit for HERCULES CONDENSING ABT 32 ErP       Code 3.025486

Modulating low consumption pump.

Additional mixed zone kit for MAGIS HERCULES     Code 3.023314
All-purpose connection kit for wall-hung combi boilers       Code 3.011667

For wall-hung combi boilers and also for wall-hung with built-in storage tank.

Anti freeze protection kit -15 °C  VICTRIX PRO       Code 3.024513

Usable in outdoor installations for minimum temperature as low as -15 °C.

Anti-freeze protection kit -15 °C for VICTRIX Superior ErP/X       Code 3.015348

Per protezione antigelo fino a -15°C.
Per VICTRIX SUPERIOR ErP/PLUS ErP.

Anti-freeze protection kit -15 °C        Code 3.017324
For VICTRIX MAIOR TT/X TT ErP, VICTRIX TT, VICTRIX EXA ErP, VICTRIX ZEUS SUPERIOR ErP e VICTRIX ZEUS 26 ErP, VICTRIX R 24 2 ErP
Anti-freeze protection kit MAGIS VICTRIX     Code 3.023770
Until -15 °C
Anti-scale kit for AVIO/ZEUS kW      Code 3.013061
Anti-scale kit for HERCULES Condensing ErP      Code 3.019999

Per apparecchi posti all'interno degli edifici o in OMNI CONTAINER, il dosatore di polifosfati è l'optional che consente di rispettare le condizioni imposte dal Decreto Interministeriale 26 Giugno 2015. Tale decreto prevede obbligatoriamente per gli impianti destinati alla produzione di acqua calda sanitaria il trattamento dell'acqua (trattamento chimico di condizionamento o di addolcimento) nei casi in cui la durezza sia oltre i 15 gradi francesi.
Kit per HERCULES CONDENSING ErP.

Anti-scale kit for HERCULES Solar 26 1A     Code 3.020498
Anti-scale kit for MAGIS HERCULES ErP    Code 3.023316
Anti-scale kit for MAGIS VICTRIX     Code 3.023310
Only for internal installation of MAGIS VICTRIX
Anti-scale kit      Code 3.016305

Available for: MAIOR EOLO, NIKE Mini 28 kW Special and MINI NIKE/EOLO.

Anti-scale kit for NIKE/EOLO Star      Code 3.013860

For NIKE STAR 24 ErP and EOLO STAR.

Anti-scale kit for VICTRIX Superior ErP, VICTRIX TT ErP and MAGIS COMBO       Code 3.017323

For VICTRIX SUPERIOR ErP, VICTRIX MAIOR TT, VICTRIX TT ErP, VICTRIX EXA and MAGIS COMBO.

Anti-scale kit for VICTRIX ZEUS Superior kW and VICTRIX Zeus      Code 3.013499

DIMV2 TOP 2 ZONE

DIM V2 TOP 2 ZONECARV2 (Comando Amico Remoto modulante)

DIM V2 TOP 2 ZONE

Anti-scale kit for water heater      Code 3.014114
Automatic valve kit for expansion vessel        Code 3.023005
As standard for a packs.
Automatically shuts the passage of fluid during maintenance of the expansion vessel.
BASIC BOX Container      Code 3.020714

Recessed frame and 4 pipes with interception cocks.

BASIC BOX TOP Container      Code 3.021034

Recessed frame and 4 pipes with interception cocks.

Balancing valve kit for BASIC BOX      Code 3.020680

Valve to stabilize the flow-rate in the single housing unit in case of any changes.

Basic free-standing 45° installation kit for 1 vertical CP4 XL/M Flat-Plate Collector        Code 3.022674
The kit includes: 4 profiles , 2 collector side fixing brackets.
Bracket kit for wall mounting inertial storage tank for MAGIS COMBO     Code 3.027290
Bracket kit for wall mounting inertial storage tank 75 litres code 3.027288.
 
By-pass kit for VICTRIX PRO 35/55      Code 3.024519
The kit is envisaged on those systems (without hydraulic manifold) in which the hydraulic flow can be under 850 l/h.
Insulation as standard.
Centralized counter kit 10 litres/pulse BASIC BOX      Code 3.019232
Including bulb pockets and probes pairs. For pipes from ½" to 1 ½".
The kit must be combined with an appropriate conventional flow with two-wire connection, not provided.
Centralized counter kit 100 litres/pulse BASIC BOX      Code 3.019233
Including bulb pockets and probes pairs. For pipes from 2" to DN 80.
The kit must be combined with an appropriate conventional flow with two-wire connection, not provided.
Clock kit for Recirculation       Code 3.015431
Condensate discharge pump kit      Code 3.026841

For floor standing boilers: compact condensate drain pump kit.

Condensate discharge pump kit      Code 3.026374

For wall-hung boilers: compact condensate drain pump kit.

Condensate discharge pump kit      Code 3.020002

For HERCULES Condensing ErP, HERCULES Solar 26 2 ErP and MAGIS HERCULES.

Condensate neutralizer kit ARES Tec up to 1500 kW      Code 3.023662

With grains.

Condensate neutralizer kit for cascade installation      Code 3.019464
Necessary to neutralize the acidity of the condensation.
Inclusive of granulate.
Condensate neutralizer kit for single installation VICTRIX PRO      Code 3.019857
Necessary to neutralize the acidity of the condensation. Inclusive of granulate.
Connection kit for 1 CSV 14 Vacuum Collector        Code 3.022796
Multiple CSV 14 Vacuum Collectors shall be connected by means of the ¾" M-F threaded fittings and the gaskets already present on the collectors.
The kit includes: fittings for Ø 18 copper pipes and DN 16 and DN 20.
Connection kit for 1 vertical CP4 XL/M Flat-Plate Collector        Code 3.022797
The kit includes: fittings for Ø 18 copper pipes and DN 16 and DN, 20 steel pipes, 2 plugs for CP4 XL/M.
(To be used for sets of 1 to 6 collectors in series)
Connection kit for EOLO Extra 24 kW       Code 3.019335
Connection kit for EOLO Extra 28 kW and EOLO Extra kW HP       Code 3.019329
Connection kit for MAIOR EOLO and MINI EOLO 28       Code 3.021453
Connection kit for NIKE Mini 28 kW Special       Code 3.016671
Connection kit for NIKE/EOLO Star 24 and MINI NIKE/EOLO 24    Code 3.015229
Connection kit for R410A circuit      Code 3.026089
Connection kit for UB Inox 200-2 or UB Inox 120-2 in parallel     Code 3.022212
Connection kit for VICTRIX 26       Code 3.017494
Connection kit for VICTRIX X 12/24     Code 3.017495
Connection kit for VICTRIX X TT, VICTRIX X TT ErP and VICTRIX EXA 24 X ErP     Code 3.024907

For the installation of heating only boilers.

Connection kit for VICTRIX Zeus 26       Code 3.020505
Connection kit for additional vertical CP4 XL/M Flat-Plate Collector        Code 3.019085
The kit includes: hydraulic fittings to connect up to 3 CP4 XL/M Flat-Plate Collectors in series.
Connection kit for double solar pump stations        Code 3.019096
The kit includes: hydraulic fittings.
Connection kit for single solar pump stations        Code 3.019095
The kit includes: hydraulic fittings.
Connection kit with flexible pipes and shut-off knobs 1"     Code 3.025954
Cover for CP4 M Flat-Plate Collector       Code 1.028522
Allows to cover the collector to guarantee its integrity until it is filled.
Cover for CP4 XL Flat-Plate Collector       Code 1.033271
Allows to cover the collector to guarantee its integrity until it is filled.
Cover for CSV 14 Vacuum Collector       Code 1.033273
Allows to cover the collector to guarantee its integrity until it is filled.
Cover kit for CAESAR 14    Code 3.014201
Cover kit for Super CAESAR 17    Code 3.015980
Cover kit for VICTRIX 26/ X 24/ X 12    Code 3.017330
Cover kit for VICTRIX Superior 32 ErP/ 32 X ErP    Code 3.017209

Per funzionamento in luoghi parzialmente protetti.
Per caldaie MAGIS VICTRIX ErP, VICTRIX SUPERIOR ErP, VICTRIX SUPERIOR 32 PLUS ErP.

D.H.W. expansion vessel for AVIO/ZEUS kW       Cod. 3.017744
D.H.W. expansion vessel for VICTRIX Zeus       Code 3.020400
  • Instructions and warning book
DIM 2 ZONES ErP       Code 3.025607
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
Hydraulic manifold, 2 low-consumption pumps and electronic board.
DIM 3 ZONES ErP       Cod. 3.025608
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 3 low consumption pumps and electronic board.
DIM BASIC ErP      Code. 3.025606
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
Hydraulic manifold and 1 low-consumption pump.
DIM H-2LT ErP       Code 3.025610

Kit for mixed systems with 2 low temperature zones and 1 high temperature zone.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 3 low consumption pumps, 2 mixing valves and electronic board.

DIM H-LT ErP       Code 3.025609
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 2 low consumption pumps, 1 mixing valve and electronic board.
DN 16 steel pipe connection kit for collectors        Code 3.019125
The kit includes:
double DN 16 insulated 15 m long steel pipe integrated cable for solar collector temperature probe.
DN 20 steel pipe connection kit for collectors        Code 3.020354
The kit includes:
double DN 20 insulated 15 m long steel pipe integrated cable for solar collector temperature probe hydraulic fittings for connections.
Data concentrator kit for 32 users (without display) BASIC BOX      Code 3.023032

Device for data acquisition. For commissioning and data management it is necessary the software code 3.023037.

Data concentrator kit for 60 users (with display) BASIC BOX      Code 3.023034

Device for the commissioning and direct data reading.

Data concentrator kit for 60 users (without display) BASIC BOX      Code 3.023033

Device for data acquisition. For commissioning and data management it is necessary the software code 3.023037.

Dehumidifier back frame kit     Code 3.022146
Dehumidifier front grille kit     Code 3.022147
Dehumidifier kit     Code 3.021529
Only for recessed installation with codes 3.022146 and 3.022147

 

Distribution manifold for 1 direct and 1 mixed temperature zones     Cod. 3.026301

Kit to be used without system manager controller. Dedicated to MAGIS PRO ErP.

  • Instruction booklet
Distribution manifold kit for 1 direct and 2 mixed temperature zones      Code 3.021527
The kit includes an expansion for the system controller for each zone, a 24 Vac transformer and an NTC probe for each mixed delivery.
Wall-hung or recessed installation. Low consumption pumps.
Distribution manifold kit for 2 mixed temperature zones     Code 3.021528
The kit includes an expansion for the system controller for each zone, a 24 Vac transformer and an NTC probe for each delivery.
Wall-hung or recessed installation. Low consumption pumps.
Domestic cold water counter kit for BASIC BOX/BASIC BOX TOP      Code 3.020719

Volumetric counter

Domestic hot water counter kit for BASIC BOX/BASIC BOX TOP      Code 3.020718

Volumetric counter

Double solar pump station (1-6 l/min) ErP        Code 3.025664
The kit includes: circulation pump, 6 bar safety valve, 0-10 bar pressure gauge, one-way ball valve, thermometer and connection to the safety unit, flow rate regulated and filling and draining valve, filling valve, draining valve, insulation.
1" hydraulic connections, 230 V ~ power supply voltage.
Double solar pump station (2-12 l/min) ErP        Code 3.025665
The kit includes: circulation pump, 6 bar safety valve, 0-10 bar pressure gauge, one-way ball valve, thermometer and connection to the safety unit, flow rate regulated and filling and draining valve, filling valve, draining valve, insulation.
1" hydraulic connections, 230 V ~ power supply voltage.
Double solar pump station (8-28 l/min) ErP        Code 3.025666
The kit includes: circulation pump, 6 bar safety valve, 0-10 bar pressure gauge, one-way ball valve, thermometer and connection to the safety unit, flow rate regulated and filling and draining valve, filling valve, draining valve, insulation.
1" hydraulic connections, 230 V ~ power supply voltage.
Electronic anode kit for Storage Tank Unit up to 500 litres      Code 3.020344
Can be used instead of magnesium anodes, requires no periodical replacement.
Electronic counter kit for BASIC BOX/BASIC BOX TOP      Code 3.020715

Counter for cooling and heating systems, including three-way diverter valve.

Fixing elements kit for CP4 XL/M Flat-Plate Collector        Code 3.022922
This kit must always be added when using the kits Code 3.019105 and Code 3.022776.
The kit includes: collector side fixing brackets and 1 intermediate bracket.
Frame connection kit for additional CP4 XL/M Flat-Plate Collector        Code 3.022681
The kit includes: 2 brackets.
The kit allows to mechanically connect two frames together when installing more than one collector.
Frame connection kit for additional CSV 14 Vacuum Collector        Code 3.022735
The kit includes: 2 brackets.
The kit allows to mechanically connect two frames together when installing more than one collector.
Frame on tiles kit for 1 horizontal CP4 XL/M Flat-Plate Collector        Code 3.022749
The kit includes: 2 horizontal profiles.
(the profiles must be shortened when using CP4 M)
Frame on tiles kit for 1 vertical CP4 XL/M Flat-Plate Collector        Code 3.022670
The kit includes: 2 horizontal profiles.
Frame on tiles kit for 1 vertical CSV 14 Vacuum Collector        Code 3.022701
Installation on tiles on sloped roofs requires the use of specific support frames which consist in 2 horizontal aluminium profiles on which the CSV 14 Vacuum Collector is fixed. In order to fix the frames, use the relative support brackets. The kit includes: 2 horizontal profiles.
Frame on tiles kit for 2 vertical CP4 XL/M Flat-Plate Collectors        Code 3.022671
The kit includes: 2 horizontal profiles.
Free-standing 45° installation extension kit for vertical CP4 XL/M Flat-Plate Collector        Code 3.022677
The kit includes: 2 profiles , 1 fixing clamp with hole , 1 mounting template (to be removed after installation).
Free-standing 45° installation kit for 1 Flat-Plate Collector        Code 3.022750
The kit includes: 4 profiles, 2 collector side fixing brackets.
(the horizontal profiles must be shortened when using CP4 M)
Free-standing 45° installation kit for 1 vertical CSV 14 Vacuum Collector        Code 3.022733
Free-standing installation on flat roofs, terraces or on the ground with a 45° inclination require the use of specific aluminium profiles which allow installation of the CSV 14 Vacuum Collectors. Appropriate systems must be used for fixing based on the capacity of the installation of withstanding the action of atmospheric agents, especially wind. In addition to the kits, the support frame kit for the vertical CSV 14 Vacuum Collector and eventually the extra CSV 14 frame connection kit must be provided.
The kit includes: 2 profiles collector fixing bracket.
Gas pressure regulation kit for water heater JULIUS     Code 3.014607
Granulate for condensate neutralizer VICTRIX PRO      Code 3.019865
Extra granulate for condensation passivator kit code 3.019857.
Granulate kit for condensate neutralizer ARES Tec (25 kg)      Code 3.023663
High temperature second zone kit for HERCULES SOLAR 26 ErP, HERCULES CONDENSING ErP        Code 3.025484
Modulating low consumption pump.
Horizontal buffer tank with capacity of 100 litres     Code 3.025063
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 200 litres     Code 3.025064
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 25 litres     Code 3.025061
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 75 litres     Cod. 3.025062
For AUDAX TOP ErP.
Hydraulic manifold kit DN 100 for 2 VICTRIX PRO 80/100/120 in cascade      Code 3.023959
Kit to connect 2 VICTRIX PRO 80/100/120 in cascade installation; it includes a 2 way interception valve, a 3-way interception valve and a non-return valve for each generator.
Insulation as standard.
Hydraulic manifold kit DN 100 for additional VICTRIX PRO 80/100/120 in cascade      Code 3.023960
In combination with kit 3.023959 serves to connect from 3 to 5 VICTRIX PRO 80/100/120 boilers in cascade installation (one kit required for each additional boiler); includes a 2-way interception valve, a 3-way interception valve and a non-return valve.
Insulation as standard.
Hydraulic manifold kit G 2 ½" for 2 VICTRIX PRO 35/55 in cascade      Code 3.023953
Kit for connection of 2 VICTRIX PRO 35/55 in cascade installation; includes a 2-way valves, a 3-way interception valvem and a non-return valve for each generator.
Insulation as standard.
Hydraulic manifold kit for VICTRIX PRO 35/55      Code 3.023951
Specially sized for large thermal systems with high water content. Equipped with sludge collection filter on the return pipe.
Insulation as standard.
Hydraulic manifold kit for VICTRIX PRO 80/100/120      Code 3.023952
Specially sized for large thermal systems with high water content. Equipped with sludge collection filter on the return pipe.
Insulation as standard
Hydraulic manifold kit for VICTRIX PRO cabinet      Code 3.027189

To install inside the cabinet kit.

Hydraulic manifold kit G 2 ½" for additional VICTRIX PRO 35/55 in cascade      Code 3.023954
In combination with kit 3.023953, it serves to connect from 3 to 5 VICTRIX PRO 35/55 boilers in cascade installation (one kit required for each additional boiler); includes a 2-way interception valve, a 3-way interception valve and a non-return valve.
Insulation as standard.
Hydraulic separator for 100 kW installations      Code 3.020839
Separator with G2 ½" threaded connectors.
Insulation as standard.
Hydraulic separator for 200 kW installations      Code 3.021377
Separator with G2 ½" threaded connectors.
Insulation as standard.
Hydraulic separator for 350 kW installations      Code 3.023965
Separator with threaded connectors - DN 100.
Insulation as standard.
Hydraulic separator for 400 kW installations      Code 3.021378
Separator with G2 ½" threaded connectors on boiler side - DN 100 on system side.
Insulation as standard.
Hydraulic separator for 600 kW installations      Code 3.023962
Separator with threaded connectors - DN 100.
Insulation as standard.
Hydraulic separator from ARES Tec 150 kW to ARES Tec 350 kW      Code 3.023659

To be mainly used when the pump is independently dimensioned by the designer.

Hydraulic separator from ARES Tec 440 kW to ARES Tec 900 kW      Code 3.023660

To be mainly used when the pump is independently dimensioned by the designer.

IPX4D protection box kit for cascade safety kit      Code 3.024038
IPX4D protection box kit for single boiler safety kit VICTRIX PRO      Code 3.024028
Integration electric resistance kit 2, 4 or 6 kW for heating system     Code 3.021525

For internal installation

Integrative 1,5 kW electric resistance kit for NATURAL SOL       Code 3.020341
Ideal to guarantee the anti-freeze function, can be calibrated by a specific thermostat.
Low consumption circulator kit for BASIC BOX TOP      Code 3.021002

For cooling and heating systems.

Low temperature safety kit     Code 3.013794
Low temperature second zone kit for HERCULES SOLAR 26 2 ErP, HERCULES CONDENSING ErP       Code 3.025483

Modulating low consumption pump.

Low temperature zones safety kit DIMV2 TOP 2/3 ZONES       Code 3.013794
Magnetic cyclone filter kit       Code 3.024176

Magnetic cyclone filter kit to prevent system ferrous residual (only for internal installation).
Available for: VICTRIX Superior TOP/X, VICTRIX TT, VICTRIX Zeus kW, VICTRIX Zeus Superior kW, VICTRIX and VICTRIX X.

Mixing valve kit for BASIC BOX/BASIC BOX TOP      Code 3.020947

Valve for domestic hot water comfort temperature setting.

NATURAL SOL by-pass kit       Code 3.022453
Can be used to empty the storage tank during winter.
Outdoor casing for safety kit and hydraulic separator from ARES Tec 150 kW to ARES Tec 350 kW      Code 3.023670

In case of outdoor installation of the safety kits and of the hydraulic separator with pump, appropriate casing kits are available to protect from the athmospheric agents.

Outdoor casing for safety kit and hydraulic separator from ARES Tec 440 kW to ARES Tec 900 kW      Code 3.023671

In case of outdoor installation of the safety kits and of the hydraulic separator with pump, appropriate casing kits are available to protect from the athmospheric agents.

Outdoor casing for safety kit and plate heat exchanger from ARES Tec 150 kW to 350 kW      Code 3.023672

In case of outdoor installation of the safety kit with pump and plate heat exchanger, casing kits are available to assure protection from athmospheric agents.

Outdoor casing for safety kit and plate heat exchanger from ARES Tec 440 kW to 900 kW      Code 3.023673

In case of outdoor installation of the safety kit with pump and plate heat exchanger, casing kits are available to assure protection from athmospheric agents.

Plates heat exchanger kit for AUDAX connection to MAGIS HERCULES     Code 3.023355

To be installed inside MAGIS HERCULES ErP, to separate AUDAX TOP ErP from the boiler.
Low consumption pump and connection pipes as standard.

Pressure - temperature safety valve kit for NATURAL SOL       Code 3.020342

Setted at 6 bar and 94 °C.

Recessed frame extension kit for CP4 XL/M Flat-Plate Collector        Code 3.023028
The kit includes: intermediate frame around collectors.
Recessed kit for 1 Flat-Plate Collector        Code 3.022213
The kit includes: special waterproof trays, perimeter frames, waterproofing sheath.
Recessed kit for 1 Vacuum Collector        Code 3.022215
Recessed installation on sloped roofs uses kits which allow integrating the CSV 14 Vacuum Collectors In-roof.
The collector is fixed directly on the roof (without using support frames) by means of fixing systems that must be provided according to the type of covering.
The kit includes: special waterproof trays, upper frame, waterproofing sheath.
Recirculation kit UB Inox 120-2     Code 3.022199
Only probe pipe.
Recirculation kit UB Inox 80-2     Code 3.022198
Only probe pipe.
Recirculation kit UB Inox Solar 200-2 and UB Inox 200-2       Code 3.022200
Only probe pipe.
Recirculation kit       Code 3.015380
Domestic hot water pump included.
Available for: ZEUS kW, ZEUS Superior kW, VICTRIX Zeus Superior kW, AVIO kW and VICTRIX Zeus.

Recirculation kit        Code 3.020001

Domestic hot water pump included.
Available for: HERCULES Condensing ErP and HERCULES SOLAR 26 2 ErP.
Recirculation kit for VICTRIX ZEUS Superior kW       Code 3.013498

Only probe pipe, pump is not included.
Available for VICTRIX Zeus Superior kW.

Recirculation kit for VICTRIX Zeus       Code 3.012944

Only probe pipe, not pump included.
Available for VICTRIX Zeus.

Recirculation kit with pump for MAGIS HERCULES     Code 3.023315

It's possible install this kit inside MAGIS HERCULES.

Recirculation pipe kit for 2 UB Inox 120-2 or 2 UB Inox 200-2 in parallel       Code 3.022201
Safety kit DN 100 for VICTRIX PRO 80/100/120 in cascade      Code 3.023961
The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure.
Insulation as standard.
Safety kit complete with pump and hydraulic separator for ARES 150 Tec      Code 3.023645

DIMV2 TOP 2 ZONE

DIM V2 TOP 2 ZONECARV2 (Comando Amico Remoto modulante)

DIM V2 TOP 2 ZONE

The following kit includes a "Y" filter, a modulating pump class A, an hydraulic separator and following safety devices: pressure gauge with pipe damper and manometer cock, thermometer, inspection openings, stube pipe G1 ¼'' for inserting safety valves, safety thermostat, pressure switch for minimum pressure with manual reset, additional stube pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve (2 for 660/770/900 kW versions), drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit complete with pump and hydraulic separator for ARES 900 Tec     Code 3.023649
The following kit includes a "Y" filter, a modulating pump class A, an hydraulic separator and following safety devices: pressure gauge with pipe damper and manometer cock, thermometer, inspection openings, stube pipe G1 ¼'' for inserting safety valves, safety thermostat, pressure switch for minimum pressure with manual reset, additional stube pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve (2 for 660/770/900 kW versions), drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit complete with pump and hydraulic separator for ARES Tec 200/250       Code 3.023646
The following kit includes a "Y" filter, a modulating pump class A, an hydraulic separator and following safety devices: pressure gauge with pipe damper and manometer cock, thermometer, inspection openings, stube pipe G1 ¼'' for inserting safety valves, safety thermostat, pressure switch for minimum pressure with manual reset, additional stube pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve (2 for 660/770/900 kW versions), drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit complete with pump and hydraulic separator for ARES Tec 200/250       Code 3.023646
The following kit includes a "Y" filter, a modulating pump class A, an hydraulic separator and following safety devices: pressure gauge with pipe damper and manometer cock, thermometer, inspection openings, stube pipe G1 ¼'' for inserting safety valves, safety thermostat, pressure switch for minimum pressure with manual reset, additional stube pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve (2 for 660/770/900 kW versions), drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit complete with pump and hydraulic separator for ARES Tec 300/350 kW      Code 3.023647
The following kit includes a "Y" filter, a modulating pump class A, an hydraulic separator and following safety devices: pressure gauge with pipe damper and manometer cock, thermometer, inspection openings, stube pipe G1 ¼'' for inserting safety valves, safety thermostat, pressure switch for minimum pressure with manual reset, additional stube pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve (2 for 660/770/900 kW versions), drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit complete with pump and hydraulic separator from ARES Tec 440 kW to ARES Tec 770 kW      Code 3.023648
The following kit includes a "Y" filter, a modulating pump class A, an hydraulic separator and following safety devices: pressure gauge with pipe damper and manometer cock, thermometer, inspection openings, stube pipe G1 ¼'' for inserting safety valves, safety thermostat, pressure switch for minimum pressure with manual reset, additional stube pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve (2 for 660/770/900 kW versions), drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit complete with pump and plate heat exchanger for ARES 660 Tec      Code 3.023653
Ideal for system solutions where the primary circuit of the boiler needs to be completely separate from the one of the plant, like for example in presence of old-fashioned plants with high risks of dirt inside the circuit, disjunctions between open and closed vessel circuits or to allow the use of anti-freeze liquid in smaller quantities in case of installation of the boiler outdoors.
The kit includes a 316 L stainless steel plate heat exchanger, a modulating pump class A, a 8 litres expansion vessel (150/350 kW versions) and 24 litres (440/900 kW versions), an automatic air vent, delivery/return pipe, a drain valve, flanges/adapters, connectors, adjustable support components and the following safety devices: 1 safety valve 5 bar (2 valves for models 660/770/900), 3-way drain valve ½", manometer and dumper tube for manometer, thermometer with trap, minimum pressure switch with manual reset, safety pressure switch, inspection thermostat, inspection opening, coupling M/F ½'', paddle flow switch and stube pipes adapters.
Safety kit complete with pump and plate heat exchanger for ARES 770 Tec      Code 3.023654
Ideal for system solutions where the primary circuit of the boiler needs to be completely separate from the one of the plant, like for example in presence of old-fashioned plants with high risks of dirt inside the circuit, disjunctions between open and closed vessel circuits or to allow the use of anti-freeze liquid in smaller quantities in case of installation of the boiler outdoors.
The kit includes a 316 L stainless steel plate heat exchanger, a modulating pump class A, a 8 litres expansion vessel (150/350 kW versions) and 24 litres (440/900 kW versions), an automatic air vent, delivery/return pipe, a drain valve, flanges/adapters, connectors, adjustable support components and the following safety devices: 1 safety valve 5 bar (2 valves for models 660/770/900), 3-way drain valve ½", manometer and dumper tube for manometer, thermometer with trap, minimum pressure switch with manual reset, safety pressure switch, inspection thermostat, inspection opening, coupling M/F ½'', paddle flow switch and stube pipes adapters.
Safety kit complete with pump and plate heat exchanger for ARES 900 Tec      Code 3.023655
Ideal for system solutions where the primary circuit of the boiler needs to be completely separate from the one of the plant, like for example in presence of old-fashioned plants with high risks of dirt inside the circuit, disjunctions between open and closed vessel circuits or to allow the use of anti-freeze liquid in smaller quantities in case of installation of the boiler outdoors.
The kit includes a 316 L stainless steel plate heat exchanger, a modulating pump class A, a 8 litres expansion vessel (150/350 kW versions) and 24 litres (440/900 kW versions), an automatic air vent, delivery/return pipe, a drain valve, flanges/adapters, connectors, adjustable support components and the following safety devices: 1 safety valve 5 bar (2 valves for models 660/770/900), 3-way drain valve ½", manometer and dumper tube for manometer, thermometer with trap, minimum pressure switch with manual reset, safety pressure switch, inspection thermostat, inspection opening, coupling M/F ½'', paddle flow switch and stube pipes adapters.
Safety kit complete with pump and plate heat exchanger for ARES Tec 150/200       Code 3.023650
Ideal for system solutions where the primary circuit of the boiler needs to be completely separate from the one of the plant, like for example in presence of old-fashioned plants with high risks of dirt inside the circuit, disjunctions between open and closed vessel circuits or to allow the use of anti-freeze liquid in smaller quantities in case of installation of the boiler outdoors.
The kit includes a 316 L stainless steel plate heat exchanger, a modulating pump class A, a 8 litres expansion vessel (150/350 kW versions) and 24 litres (440/900 kW versions), an automatic air vent, delivery/return pipe, a drain valve, flanges/adapters, connectors, adjustable support components and the following safety devices: 1 safety valve 5 bar (2 valves for models 660/770/900), 3-way drain valve ½", manometer and dumper tube for manometer, thermometer with trap, minimum pressure switch with manual reset, safety pressure switch, inspection thermostat, inspection opening, coupling M/F ½'', paddle flow switch and stube pipes adapters.
Safety kit complete with pump and plate heat exchanger for ARES Tec 250/350 kW      Code 3.023651
Ideal for system solutions where the primary circuit of the boiler needs to be completely separate from the one of the plant, like for example in presence of old-fashioned plants with high risks of dirt inside the circuit, disjunctions between open and closed vessel circuits or to allow the use of anti-freeze liquid in smaller quantities in case of installation of the boiler outdoors.
The kit includes a 316 L stainless steel plate heat exchanger, a modulating pump class A, a 8 litres expansion vessel (150/350 kW versions) and 24 litres (440/900 kW versions), an automatic air vent, delivery/return pipe, a drain valve, flanges/adapters, connectors, adjustable support components and the following safety devices: 1 safety valve 5 bar (2 valves for models 660/770/900), 3-way drain valve ½", manometer and dumper tube for manometer, thermometer with trap, minimum pressure switch with manual reset, safety pressure switch, inspection thermostat, inspection opening, coupling M/F ½'', paddle flow switch and stube pipes adapters.
Safety kit complete with pump and plate heat exchanger for ARES Tec 440/550 kW      Code 3.023652
Ideal for system solutions where the primary circuit of the boiler needs to be completely separate from the one of the plant, like for example in presence of old-fashioned plants with high risks of dirt inside the circuit, disjunctions between open and closed vessel circuits or to allow the use of anti-freeze liquid in smaller quantities in case of installation of the boiler outdoors.
The kit includes a 316 L stainless steel plate heat exchanger, a modulating pump class A, a 8 litres expansion vessel (150/350 kW versions) and 24 litres (440/900 kW versions), an automatic air vent, delivery/return pipe, a drain valve, flanges/adapters, connectors, adjustable support components and the following safety devices: 1 safety valve 5 bar (2 valves for models 660/770/900), 3-way drain valve ½", manometer and dumper tube for manometer, thermometer with trap, minimum pressure switch with manual reset, safety pressure switch, inspection thermostat, inspection opening, coupling M/F ½'', paddle flow switch and stube pipes adapters.
Safety kit G 2" ½ for VICTRIX PRO 35/55 in cascade      Code 3.023955
The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure.
Insulation as standard.
Safety kit single boiler VICTRIX PRO      Code 3.023949
The kit includes thermometer, thermometer holder, lock, thermostatwith manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard.
Safety kit with filter for ARES 900 Tec      Code 3.023658
To be mainly used when the pump is dimensioned by designer. The safety kit includes: pressure gauge with pipe damper and, manometer cock, thermometer, inspection openings, stub pipes G1 ¼'' for inserting safety valves, safety thermostat, manual reset pressure switch for minimum pressure, additional stub pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve, drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit with filter from ARES Tec 150 kW to ARES Tec 350 kW      Code 3.023656
To be mainly used when the pump is dimensioned by designer. The safety kit includes: pressure gauge with pipe damper and, manometer cock, thermometer, inspection openings, stub pipes G1 ¼'' for inserting safety valves, safety thermostat, manual reset pressure switch for minimum pressure, additional stub pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve, drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety kit with filter from ARES Tec 440 kW to ARES Tec 770 kW      Code 3.023657
To be mainly used when the pump is dimensioned by designer. The safety kit includes: pressure gauge with pipe damper and, manometer cock, thermometer, inspection openings, stub pipes G1 ¼'' for inserting safety valves, safety thermostat, manual reset pressure switch for minimum pressure, additional stub pipe G1, safety pressure switch and differential flow switch.
The kit does not include the tested expansion tank, safety valve, drain valve and manometer, since these need to be sized according to the characteristics of the system.
Safety valve 7 bar and 12 litres expansion vessel kit for RAPAX V2     Code 3.025231
For RAPAX V2, heat pump water heater.
It can be fixed into wall thanks to brackets (as standard).
Sanitary priority 3-way valve kit       Code 3.020633
Shut off knobs       Code 3.5324

For wall-hung outdoor boilers.

Shut off knobs with filter       Code 3.015854
Available for: ZEUS kW, ZEUS Superior kW, VICTRIX Zeus Superior kW, AVIO kW, VICTRIX Zeus, VICTRIX Superior TOP/X, VICTRIX, VICTRIX X, VICTRIX R, EOLO Extra kW HP and MAIOR EOLO.
Shut-off knobs       Code 3.014948
Single solar pump station (1-6 l/min) ErP        Code 3.025662
The kit includes: circulation pump, 6 bar safety valve, 0-10 bar pressure gauge, one-way ball valve, thermometer and connection to the safety unit, flow rate regulated and filling and draining valve, filling valve, draining valve, insulation.
1" hydraulic connections, 230 V ~ power supply voltage.
Single solar pump station (2-12 l/min) ErP       Code 3.025663
The kit includes: circulation pump, 6 bar safety valve, 0-10 bar pressure gauge, one-way ball valve, thermometer and connection to the safety unit, flow rate regulated and filling and draining valve, filling valve, draining valve, insulation.
1" hydraulic connections, 230 V ~ power supply voltage.
Software kit to download data from the concentrator BASIC BOX      Code 3.023037

The data can be downloaded and processed on Windows computers only.

Solar collector probe       Code 3.019374
To be used to manage the solar system coupled to thermal plants using the cascade and zone regulator.
Solar collector probe       Code 3.019374
To be used to manage the solar system coupled to thermal plants using the cascade and zone regulator.
Solar connection kit for MAGIS HERCULES     Code 3.023339
Solar panel connection kit for UB Inox 120-2      Code 3.022197
Including pipes and fittings for connection in template.
Solar panel connection kit for UB Inox 200-2      Code 3.022195
Including pipes and fittings for connection in template.
Solar panel connection kit for UB Inox 200-2 or UB Inox 120-2 in parallel     Code 3.022196

Including pipes and fittings for connection in template.

Solar panel kit for HERCULES Condensing ErP       Code 3.019998

It includes pipes and fittings. For connecting 1 Flat-Plate or Vacuum Collector.
It must be used coupled with the typical BASIC SOL TOP and BASIC SOL LUX TOP packs.

Solar valve        Code 3.018911
Allows the connection between combi boiler and solar system.
Available for: VICTRIX Superior TOP, VICTRIX, MAIOR EOLO, NIKE Mini 28 kW Special, MINI NIKE/EOLO and NIKE/EOLO Star.
Storage tank connection kit for VICTRIX Superior TOP 32 X E       Code 3.022848
Storage tank connection kit for VICTRIX X TT ErP     Code 3.024609

Storage tank connection kit for VICTRIX X TT ErP, VICTRIX EXA 24 X ErP, VICTRIX X TT and VICTRIX MAIOR 35 X TT ErP.

Storage tank sensor kit (for managing the storage tank as a zone)       Code 3.015268

For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.

System filling pump station       Code 3.018742
Ideal for correctly filling the forced circulation solar system with the waterglycol solution.
Tank of glycol for CP4 XL/M Flat-Plate Collectors and CSV 14 Vacuum Collectors       Code 1.031756
The kit includes:
one 20 kg can of glycol and propylene already mixed and ready to use.
Antifreeze protection up to - 25 °C.
Three-way valve kit connection to a separate storage tank VICTRIX PRO      Code 3.023950
The kit includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard.
VICTRIX PRO Cabinet kit      Code 3.027188

Floor-standing cabinet, it can be installed outdoor.

Vent kit and fitting for Ø 22 mm pipe for horizontal CP4 XL/M Flat-Plate Collector        Cod. 3.022849
This kit is used in applications with horizontal CP4 XL/M Flat-Plate.
Vertical inertial storage tank 75 litre for MAGIS COMBO     Code 3.027288
For solutions with hybrid heat pumps MAGIS COMBO.
Wall-hung (with bracket option kit) or floor-standing installation.
Wall mounting brackets for AUDAX 6/8 kW     Code 3.022154
kit containing bottom guard for condensing boilers      Code 3.027341

For wall-hung condensing boilers.

¾" Mixing valve        Code 3.019099
Range 42-60 °C.
The kit includes:
1 thermostatic mixing valve with a 42 °C - 60 °C adjustment range and maximum inlet temperature of 90 °C.
Available for: VICTRIX Superior TOP, VICTRIX, MAIOR EOLO, NIKE Mini 28 kW Special, MINI NIKE/EOLO, NIKE/EOLO Star, CAESAR 14 and Super CAESAR 17.
¾" nut kit for DN 16 steel pipe        Code 1.027255
For connection to solar collectors.
Ø 18 copper pipe connection kit for collectors        Code 3.019089
The kit includes:
double Ø 18 mm insulated 15 m long copper pipe integrated cable for solar collector temperature probe.
"Free standing" support frame kit VICTRIX PRO      Code 3.024246
Designed to resolve installation situations in which the wall of the furnace room is not usable. With this modular construction, it is necessary to order a kit for every boiler installed.
Approved also for installation outside the building.
QUALITY IN SERVICES
MADE IN ITALY
50 years of experience
OVER 6 MILLION BOILERS INSTALLED