VICTRIX PRO 55 2 ErP
prompt answers within 24 hours.
Technical data VICTRIX PRO 55 2 ErP |
|
---|---|
Code | 3.025618 |
custom | Array |
C.H. Energy class | A |
Heat output ref. 80-60°C kW | 49,9 |
Heat output ref. 50-30°C kW | 54,8 |
Efficiency at nominal heat output ref. 80-60 °C | 97,3% |
Efficiency at nominal heat output ref. 50-30 °C | 106,8% |
Dimensions (HxWxD) mm | 843 x 442 x 452 |
Modulating heat output | 10 - 100% |
Technical data VICTRIX PRO 55 2 ErP |
|
---|---|
Code | 3.025618 |
Product plus | BIM READY |
C.H. Energy class | A |
Heat output ref. 80-60°C kW | 49,9 |
Heat output ref. 50-30°C kW | 54,8 |
Efficiency at nominal heat output ref. 80-60 °C | 97,3% |
Efficiency at nominal heat output ref. 50-30 °C | 106,8% |
Dimensions (HxWxD) mm | 843 x 442 x 452 |
Modulating heat output | 10 - 100% |
Wall hung, modular condensing boiler for heating only. 50 kW heat output.
Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO ErP boiler is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO ErP can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO 55 2 ErP belongs to class 5, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%
* default settings
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%
* default settings
Cascade and zone regulator kit Cod.3.015244
External probe Cod.3.015266
To be used when external probe as standard in outdoor unit is not correctly exposed.
Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%
* default settings
External probe (for installation in battery) Cod.3.024511
Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function
Flow probe Cod.3.015267
Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.
Modulating room thermostat Cod.3.015245
Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.
Remote control for single VICTRIX PRO Cod.3.020358
This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.
System delivery probe kit for the boiler VICTRIX PRO Cod.3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
Tele-management kit 2.0 Cod.3.029832
Can be combined exclusively with the cascade and zone regulator for connection to an ethernet network or via router/modem to an ADSL line for connection to a remote system.
Wall box kit for cascade and zone regulator Cod.3.015265
If the cascade and zone regolator is not install inside an electrical box.
Zone manager kit Cod.3.015264
Horizontal concentric kit Ø 80/125 Cod.3.030782
for VICTRIX PRO 35-55-68-80 ErP.
Horizontal kit Ø 80 (to discharge in the chimney) Cod.3.015254
For VICTRIX PRO.
Terminal horizontal outlet kit Ø 80 (to discharge horizontally) Cod.3.015255
For VICTRIX PRO.
Terminal vertical outlet kit Ø 80 Cod.3.015256
For condensing boiler < 35 kW.
Terminal vertical outlet outdoor kit Ø 80 Cod.3.024295
For VICTRIX PRO.
Condensate neutralizer kit for cascade installation Cod.3.019464
Inclusive of granulate.
Hydraulic manifold kit for VICTRIX PRO 35/55 Cod.3.023951
Hydraulic separator for 200 kW installations Cod.3.021377
Hydraulic separator for 350 kW installations Cod.3.023965
Hydraulic separator for 400 kW installations Cod.3.021378
IPX4D protection box kit for cascade safety kit Cod.3.024038
IPX4D protection box kit for single boiler safety kit VICTRIX PRO Cod.3.024028
Safety kit single boiler VICTRIX PRO Cod.3.023949
Safety kit single boiler VICTRIX PRO Cod.3.023966
Solar collector probe Cod.3.019374
Storage tank sensor kit (for managing the storage tank as a zone) Cod.3.015268
For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.
Three-way valve kit connection to a separate storage tank VICTRIX PRO Cod.3.023950
Wall hung, modular condensing boiler for heating only. 50 kW heat output.
Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO ErP boiler is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO ErP can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO 55 2 ErP belongs to class 5, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).
CRONO 7 (weekly digital chronothermostat) Cod.3.021622
ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%
* default settings
CRONO 7 WIRELESS (wireless weekly digital chronothermostat) Cod.3.021624
ON/OFF room thermostat.
Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%
* default settings
Cascade and zone regulator kit Cod.3.015244
External probe Cod.3.015266
To be used when external probe as standard in outdoor unit is not correctly exposed.
Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%
* default settings
External probe (for installation in battery) Cod.3.024511
Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function
Flow probe Cod.3.015267
Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.
Modulating room thermostat Cod.3.015245
Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.
Remote control for single VICTRIX PRO Cod.3.020358
This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.
System delivery probe kit for the boiler VICTRIX PRO Cod.3.024245
Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.
Tele-management kit 2.0 Cod.3.029832
Can be combined exclusively with the cascade and zone regulator for connection to an ethernet network or via router/modem to an ADSL line for connection to a remote system.
Wall box kit for cascade and zone regulator Cod.3.015265
If the cascade and zone regolator is not install inside an electrical box.
Zone manager kit Cod.3.015264
Horizontal concentric kit Ø 80/125 Cod.3.030782
for VICTRIX PRO 35-55-68-80 ErP.
Horizontal kit Ø 80 (to discharge in the chimney) Cod.3.015254
For VICTRIX PRO.
Terminal horizontal outlet kit Ø 80 (to discharge horizontally) Cod.3.015255
For VICTRIX PRO.
Terminal vertical outlet kit Ø 80 Cod.3.015256
For condensing boiler < 35 kW.
Terminal vertical outlet outdoor kit Ø 80 Cod.3.024295
For VICTRIX PRO.
Condensate neutralizer kit for cascade installation Cod.3.019464
Inclusive of granulate.
Hydraulic manifold kit for VICTRIX PRO 35/55 Cod.3.023951
Hydraulic separator for 200 kW installations Cod.3.021377
Hydraulic separator for 350 kW installations Cod.3.023965
Hydraulic separator for 400 kW installations Cod.3.021378
IPX4D protection box kit for cascade safety kit Cod.3.024038
IPX4D protection box kit for single boiler safety kit VICTRIX PRO Cod.3.024028
Safety kit single boiler VICTRIX PRO Cod.3.023949
Safety kit single boiler VICTRIX PRO Cod.3.023966
Solar collector probe Cod.3.019374
Storage tank sensor kit (for managing the storage tank as a zone) Cod.3.015268
For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.