VICTRIX PRO 100 2 ErP

Wall-hung modular condensing boiler for heating only
The customer service provides
prompt answers within 24 hours.
Wide modulating heat output
Ideal for energy efficiency upgrade
Possible installation in cascade

Technical data VICTRIX PRO 100 2 ErP

Code 3.025620
custom Array
Heat output ref. 80-60°C kW 90,0
Heat output ref. 50-30°C kW 98,8
Efficiency at nominal heat output ref. 80-60 °C 97,5%
Efficiency at nominal heat output ref. 50-30 °C 107,0%
Dimensions (HxWxD) mm 1038 x 600 x 627
Modulating heat output 10 - 100%

Technical data VICTRIX PRO 100 2 ErP

Code 3.025620
Product plus BIM READY
Heat output ref. 80-60°C kW 90,0
Heat output ref. 50-30°C kW 98,8
Efficiency at nominal heat output ref. 80-60 °C 97,5%
Efficiency at nominal heat output ref. 50-30 °C 107,0%
Dimensions (HxWxD) mm 1038 x 600 x 627
Modulating heat output 10 - 100%

Gallery

Wall hung, modular condensing boiler for heating only. 90 kW heat output.

Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO ErP boiler is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO ErP can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO 100 2 ErP belongs to class 5, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

...

Cascade and zone regulator kit   Cod.3.015244

ON-OFF adjustment, modulation and malfunctions of the VICTRIX PRO in cascade (max 8). It can manage any climatic zone regulators in the system (max 3 plus 1 dedicated to the hot tap water circuit).
...

External probe   Cod.3.015266

To be used when external probe as standard in outdoor unit is not correctly exposed.


Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%

* default settings

...

External probe (for installation in battery)   Cod.3.024511

Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function

...

Flow probe   Cod.3.015267

Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.

...

Modulating room thermostat   Cod.3.015245

Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.

...

Remote control for single VICTRIX PRO   Cod.3.020358

This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.

...

System delivery probe kit for the boiler VICTRIX PRO   Cod.3.024245

Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

...

Tele-management kit 2.0   Cod.3.029832

Can be combined exclusively with the cascade and zone regulator for connection to an ethernet network or via router/modem to an ADSL line for connection to a remote system.

...

Wall box kit for cascade and zone regulator   Cod.3.015265

If the cascade and zone regolator is not install inside an electrical box.

...

Zone manager kit   Cod.3.015264

Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone, and allow remote control of the cascade and zone regulator.
...

2 x 45° Bend kit Ø 80/125   Cod.3.015248

Per installazione a camera stagna e tiraggio forzato (tipo C).
Per VICTRIX PRO ErP e ARES CONDENSING 50/115 ErP.

...

45° bend Ø 110/160 kit   Cod.3.031395

for VICTRIX PRO 100-120 ErP.

...

87° Bend kit Ø 80/125   Cod.3.015247

Per installazione a camera stagna e tiraggio forzato (tipo C).
Per VICTRIX PRO ErP e ARES CONDENSING 50/115 ErP.

...

87° bend kit Ø 250 for flue manifold   Cod.3.024670

For installations in central heating systems with VICTRIX PRO.
...

87° bend Ø 110/160 kit   Cod.3.031396

for VICTRIX PRO 100-120 ErP.

...

Extension pipe kit Ø 80/125 1 m long   Cod.3.018667

 

 

...

Extension pipe kit Ø 80/125 2 m long   Cod.3.015246

 

 

 

...

Extension pipe kit Ø 110/160 1 m long   Cod.3.031397

for VICTRIX PRO 100-120 ErP.

...

Extension pipe kit Ø 110/160 2 m long   Cod.3.031398

for VICTRIX PRO 100-120 ErP.

...

Extension pipe Ø 200 kit 0,5 m long for flue manifold   Cod.3.024663

For installations in central heating systems with VICTRIX PRO.  
...

Extension pipe Ø 200 kit 1 m long for flue manifold   Cod.3.024662

For installations in central heating systems with VICTRIX PRO.
...

Extension pipe Ø 250 kit 1 m long for flue manifold   Cod.3.024668

For installations in central heating systems with VICTRIX PRO.

...

Horizontal concentric kit Ø 110/160   Cod.3.031393

for VICTRIX PRO 100-120 ErP.

...

Horizontal kit Ø 80 (to discharge in the chimney)   Cod.3.015254

For VICTRIX PRO.

...

No. 2 45° bend kit Ø 200 for flue manifold   Cod.3.024664

For installations in central heating systems with VICTRIX PRO.

...

No. 2 45° bend kit Ø 250 for flue manifold   Cod.3.024669

For installations in central heating systems with VICTRIX PRO.

...

Terminal horizontal outlet kit Ø 80 (to discharge horizontally)   Cod.3.015255

For VICTRIX PRO.

...

Terminal vertical outlet kit Ø 80   Cod.3.015256

For condensing boiler < 35 kW.

...

Terminal vertical outlet outdoor kit Ø 80   Cod.3.024295

For VICTRIX PRO.

...

Vertical concentric kit Ø 80/125   Cod.3.015243

For VICTRIX PRO.

...

Condensate discharge pump kit   Cod.3.020002

For VICTRIX PRO ErP

...

Condensate neutralizer kit for cascade installation   Cod.3.019464

Necessary to neutralize the acidity of the condensation.
Inclusive of granulate.
...

Hydraulic manifold kit for VICTRIX PRO 80/100/120   Cod.3.023952

Specially sized for large thermal systems with high water content. Equipped with sludge collection filter on the return pipe.
Insulation as standard
...

Hydraulic separator for 200 kW installations   Cod.3.021377

Separator with G2 ½" threaded connectors.
Insulation as standard.
...

Hydraulic separator for 350 kW installations   Cod.3.023965

Separator with threaded connectors - DN 100.
Insulation as standard.
...

Hydraulic separator for 400 kW installations   Cod.3.021378

Separator with G2 ½" threaded connectors on boiler side - DN 100 on system side.
Insulation as standard.
...

Hydraulic separator for 600 kW installations   Cod.3.023962

Separator with threaded connectors - DN 100.
Insulation as standard.
...

IPX4D protection box kit for cascade safety kit   Cod.3.024038

...

IPX4D protection box kit for single boiler safety kit VICTRIX PRO   Cod.3.024028

...

Safety kit DN 100 for VICTRIX PRO 80/100/120 in cascade   Cod.3.023961

The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure.
Insulation as standard.
...

Safety kit single boiler VICTRIX PRO   Cod.3.023949

The kit includes thermometer, thermometer holder, lock, thermostatwith manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard.
...

Solar collector probe   Cod.3.019374

To be used to manage the solar system coupled to thermal plants using the cascade and zone regulator.
...

Storage tank sensor kit (for managing the storage tank as a zone)   Cod.3.015268

For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.

...

Three-way valve kit connection to a separate storage tank VICTRIX PRO   Cod.3.023950

The kit includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard.

Wall hung, modular condensing boiler for heating only. 90 kW heat output.

Wide modulating ratio up to 5 boilers in cascade installation, high performances with reduced consumption thanks to the 1:10 modulation range and high efficiency, the new VICTRIX PRO ErP boiler is the ideal solution for light commercial solutions in residential and commercial buildings. The new design, compact and linear, with a vertical sliding door protecting the control board, makes its installation easy even in residential buildings (according to the current regulations in force in each country).
VICTRIX PRO ErP can be used on the appropriate supporting modulation frame for floor standing installations. Certified for indoor and outdoor installations, even in unsheltered areas thanks to the IPX5D electric protection, the boiler is supplied with the -5 °C anti-freeze kit as standard.
Thanks to low emissions of carbon monoxide (CO) and nitrogen oxide (NOX), VICTRIX PRO 100 2 ErP belongs to class 5, the most environmentally-friendly class established by the European standards (UNI EN 297 e UNI EN 483).

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

...

Cascade and zone regulator kit   Cod.3.015244

ON-OFF adjustment, modulation and malfunctions of the VICTRIX PRO in cascade (max 8). It can manage any climatic zone regulators in the system (max 3 plus 1 dedicated to the hot tap water circuit).
...

External probe   Cod.3.015266

To be used when external probe as standard in outdoor unit is not correctly exposed.


Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%

* default settings

...

External probe (for installation in battery)   Cod.3.024511

Connected to the cascade and zone regulator, it optimizes energy consumption by correcting the delivery temperature to the system for smooth temperature function

...

Flow probe   Cod.3.015267

Positioned on the delivery pipe, after the hydraulic separator, it allows the cascade and zone regulator to control system temperature as well as that of any mixed zones.

...

Modulating room thermostat   Cod.3.015245

Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone. Allows control of room temperature only.

...

Remote control for single VICTRIX PRO   Cod.3.020358

This is a modulating control unit that serves to optimize climatic management of the temperature in rooms. It can only be used on systems with a single temperature control.

...

System delivery probe kit for the boiler VICTRIX PRO   Cod.3.024245

Connected to the boiler board, it measures the delivery temperature after the hydraulic manifold.

...

Tele-management kit 2.0   Cod.3.029832

Can be combined exclusively with the cascade and zone regulator for connection to an ethernet network or via router/modem to an ADSL line for connection to a remote system.

...

Wall box kit for cascade and zone regulator   Cod.3.015265

If the cascade and zone regolator is not install inside an electrical box.

...

Zone manager kit   Cod.3.015264

Electrically connected to cascade and zone regulator, serves to manage climatic conditions of one of system zone, and allow remote control of the cascade and zone regulator.
...

2 x 45° Bend kit Ø 80/125   Cod.3.015248

Per installazione a camera stagna e tiraggio forzato (tipo C).
Per VICTRIX PRO ErP e ARES CONDENSING 50/115 ErP.

...

45° bend Ø 110/160 kit   Cod.3.031395

for VICTRIX PRO 100-120 ErP.

...

87° Bend kit Ø 80/125   Cod.3.015247

Per installazione a camera stagna e tiraggio forzato (tipo C).
Per VICTRIX PRO ErP e ARES CONDENSING 50/115 ErP.

...

87° bend kit Ø 250 for flue manifold   Cod.3.024670

For installations in central heating systems with VICTRIX PRO.
...

87° bend Ø 110/160 kit   Cod.3.031396

for VICTRIX PRO 100-120 ErP.

...

Extension pipe kit Ø 80/125 1 m long   Cod.3.018667

 

 

...

Extension pipe kit Ø 80/125 2 m long   Cod.3.015246

 

 

 

...

Extension pipe kit Ø 110/160 1 m long   Cod.3.031397

for VICTRIX PRO 100-120 ErP.

...

Extension pipe kit Ø 110/160 2 m long   Cod.3.031398

for VICTRIX PRO 100-120 ErP.

...

Extension pipe Ø 200 kit 0,5 m long for flue manifold   Cod.3.024663

For installations in central heating systems with VICTRIX PRO.  
...

Extension pipe Ø 200 kit 1 m long for flue manifold   Cod.3.024662

For installations in central heating systems with VICTRIX PRO.
...

Extension pipe Ø 250 kit 1 m long for flue manifold   Cod.3.024668

For installations in central heating systems with VICTRIX PRO.

...

Horizontal concentric kit Ø 110/160   Cod.3.031393

for VICTRIX PRO 100-120 ErP.

...

Horizontal kit Ø 80 (to discharge in the chimney)   Cod.3.015254

For VICTRIX PRO.

...

No. 2 45° bend kit Ø 200 for flue manifold   Cod.3.024664

For installations in central heating systems with VICTRIX PRO.

...

No. 2 45° bend kit Ø 250 for flue manifold   Cod.3.024669

For installations in central heating systems with VICTRIX PRO.

...

Terminal horizontal outlet kit Ø 80 (to discharge horizontally)   Cod.3.015255

For VICTRIX PRO.

...

Terminal vertical outlet kit Ø 80   Cod.3.015256

For condensing boiler < 35 kW.

...

Terminal vertical outlet outdoor kit Ø 80   Cod.3.024295

For VICTRIX PRO.

...

Vertical concentric kit Ø 80/125   Cod.3.015243

For VICTRIX PRO.

...

Condensate discharge pump kit   Cod.3.020002

For VICTRIX PRO ErP

...

Condensate neutralizer kit for cascade installation   Cod.3.019464

Necessary to neutralize the acidity of the condensation.
Inclusive of granulate.
...

Hydraulic manifold kit for VICTRIX PRO 80/100/120   Cod.3.023952

Specially sized for large thermal systems with high water content. Equipped with sludge collection filter on the return pipe.
Insulation as standard
...

Hydraulic separator for 200 kW installations   Cod.3.021377

Separator with G2 ½" threaded connectors.
Insulation as standard.
...

Hydraulic separator for 350 kW installations   Cod.3.023965

Separator with threaded connectors - DN 100.
Insulation as standard.
...

Hydraulic separator for 400 kW installations   Cod.3.021378

Separator with G2 ½" threaded connectors on boiler side - DN 100 on system side.
Insulation as standard.
...

Hydraulic separator for 600 kW installations   Cod.3.023962

Separator with threaded connectors - DN 100.
Insulation as standard.
...

IPX4D protection box kit for cascade safety kit   Cod.3.024038

...

IPX4D protection box kit for single boiler safety kit VICTRIX PRO   Cod.3.024028

...

Safety kit DN 100 for VICTRIX PRO 80/100/120 in cascade   Cod.3.023961

The kit includes thermometer, thermometer holder, lock, thermostat with manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure.
Insulation as standard.
...

Safety kit single boiler VICTRIX PRO   Cod.3.023949

The kit includes thermometer, thermometer holder, lock, thermostatwith manual reset, connection tap for pressure gauge, manual reset pressure switch, gas intercepting valve trap, expansion vessel connection and pressure switch for minimum pressure. Insulation as standard.
...

Solar collector probe   Cod.3.019374

To be used to manage the solar system coupled to thermal plants using the cascade and zone regulator.
...

Storage tank sensor kit (for managing the storage tank as a zone)   Cod.3.015268

For the storage tank unit managed as a zone (with a circulator) and connected to the cascade regulator (without external 3-way valve). For solar installations managed with cascade and zone regulator two probes are necessary.

...

Three-way valve kit connection to a separate storage tank VICTRIX PRO   Cod.3.023950

The kit includes the storage tank probe. The power supply is 230 Vac.
Insulation as standard.

Related products

VICTRIX PRO 80 2 ErP
Wall-hung modular condensing boiler for heating only
VICTRIX PRO 120 2 ErP
Wall-hung modular condensing boiler for heating only

Contacts

Contact us
Customer Care