IT / EN
Skip to Content
AUDAX TOP 16 ErP
Code 3.025562
Heating output kW 15,00
Cooling output kW 16,00
Dimensions (HxWxD) mm 1363 x 908 x 326
Refrigerant gas R410A
COP 4,20
EER 3,81
Weight (kg) 116

A++

A+

Air to water inverter threephase heat pump.
15,00 kW heating output and 16,00 kW cooling output.
The AUDAX TOP air to water heat pumps are mono-bloc appliances that use outdoor air as a partially renewable heat source by transferring its thermal energy content to the central heating system. This very peculiar operation allows to reach leaving water temperature up to 60 °C, making AUDAX TOP heat pumps the ideal solution for both heating and cooling purposes and, moreover for DHW production, when combined with dedicated, separate storage tanks.
All the products in the range are equipped with built-in new low energy consumption circulation pumps and a separate control panel, supplied as standard, fit for in room installation, for the easiest and most comfortable system managent. Furthermore, the inverter technology operated built-in compressor allows a very fine power output modulation control, together with reduction of the power input, succeeding in very good performances for a higher and higher quality in indoor living conditions.
AUDAX TOP 16 ErP can be installed in stand-alone configuration or combined with a boiler working as an integrated systems, or, moreover, joined together in cascade installations. All the products in the range are certified for fully open air installation. Heat pumps best performances in heating are available in 45-50 °C maximum leaving-water-temperature conditions; otherwise, during the summer season, they represent the ideal appliance for cooling purposes, feeding fan coils systems or, as an alternative, radiant cooling systems (for floor, wall or ceiling) combined with dehumidifiers.
Threephase versions are designed for existing or new buildings, offices air conditioning.

Ideal for new buildings
Standard thermoregulation
Heating and cooling
Thermoregulation
Remote control kit       Code 3.023364
Class of device V or VI*
Contribution to the environmental heating seasonal energy efficiency 3% or 4%*
 
* as standard
System controller       Code 3.021522
Class of device VI* or VIII
Contribution to the environmental heating seasonal energy efficiency 4%* or 5%
 
* as standard
Temperature/humidity active sensor kit       Code 3.021524

To be used with radiant systems that also work in cooling mode.

Class of device V or VI*
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%*

* as standard

Room hygrostat       Code 3.023302

To be used with radiant systems that also work in cooling mode.

System controller expansion kit       Code 3.021547

Da utilizzare in presenza di sistemi integrati, solo in abbinamento al gestore di sistema (cod. 3.021522). Permette di gestire ausiliari quali: pompa di circolazione, valvola miscelatrice, deumidificatore, pompa di ricircolo, valvole 3 vie deviatrici per riscaldamento/raffrescamento. Da alimentare in bassa tensione (24 Vac).

CRONO 7 (weekly digital chronothermostat)       Code 3.021622

Available for all models.

Class of device IV* or VII
Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* as standard

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)       Code 3.021624

Available for all models.

Class of device IV* or VII
Contribution to the environmental heating energy efficiency 2%* or 3,5%

* as standard

EMR 12 VDC relay kit       Code 3.023945
SSR 6 VDC relay kit       Code 3.023946

To be used for electric integration.

Storage tank NTC probe       Code 3.019375

Allows to check the DHW temperature of a commercial Storage Tank Unit with the Immergas boiler <35 kW.
Provided as per standard on all Storage Tank Units in the catalogue.

Flue systems
Options
Distribution manifold kit for 1 direct and 2 mixed temperature zones      Code 3.021527
The kit includes an expansion for the system controller for each zone, a 24 Vac transformer and an NTC probe for each mixed delivery.
Wall-hung or recessed installation. Low consumption pumps.
Distribution manifold kit for 2 mixed temperature zones     Code 3.021528
The kit includes an expansion for the system controller for each zone, a 24 Vac transformer and an NTC probe for each delivery.
Wall-hung or recessed installation. Low consumption pumps.
Low temperature safety kit     Code 3.013794
Dehumidifier kit     Code 3.021529
Only for recessed installation with codes 3.022146 and 3.022147

 

Dehumidifier back frame kit     Code 3.022146
Dehumidifier front grille kit     Code 3.022147
Horizontal buffer tank with capacity of 25 litres     Code 3.025061
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 25 litres     Code 3.025061
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 25 litres     Code 3.025061
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 25 litres     Code 3.025061
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 75 litres     Cod. 3.025062
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 100 litres     Code 3.025063
For AUDAX TOP ErP.
Horizontal buffer tank with capacity of 200 litres     Code 3.025064
For AUDAX TOP ErP.
Thermoregulation
Flue systems
Options
 
CONTACT US
 
 
 
CUSTOMER CARE
 
QUALITY IN SERVICES
MADE IN ITALY
50 years of experience