IT / EN
Skip to Content
MAGIS COMBO 5 PLUS
Code (ref. N.G.) 3.027237
Heating output kW 5,80
Cooling output kW 6,03
Internal Unit (HxWxD) mm 787 x 440 x 400
Outdoor Unit (HxWxD) mm 638 x 880 x 364
Refrigerant gas R410A
COP 4,53
EER 3,61
Condensing Unit empty appliance (kg) 47,5

A+

A++

Split air to water, inverter-driven monophase hybrid heat pump system, consisting of outdoor heat pump unit and indoor hydronic and condensing unit. Heating only version. 

5,80 kW heating / 6,03 kW cooling capacity.

The new MAGIS COMBO heat pumps are appliances designed to use outside air as a partially renewable heat source by transferring its thermal energy content to the central heating system. MAGIS COMBO is designed to meet the highest demands, its heating temperature can reach up to 80 °C. The internal unit is designed for combination with a separate storage tank unit for domestic hot water (optional). In the domestic hot water mode, the internal unit and heat pump work on a single boiler supply/return circuit.

For installation it's necessary the degree of training required to professional people (that have to be in possess of F-GAS certification) involved in the installation and their mutual connection by means of the gas circuit. The inverter driven control allows a very fine power output modulation control, together with reduction of the power input, succeeding in high level performances for more comfortable indoor climatic conditions.

MAGIS COMBO are domestic-purpose-suit systems, and they are the ideal solution in new, high energy rating buildings, even when located in extremely cold areas, with very low outdoor-winter-temperatures.

The very compact external unit (smaller compared to the most diffused hydronic heat pump models), installable both on balcony and fully outdoor, allows to MAGIS COMBO enhanced positional flexibility together with a minimal aestethic effect on the overall style.

MAGIS COMBO is ideal for combination with photovoltaic systems.

Noiseless
Easy installation
Heating and cooling
Thermoregulation
Remote control kit       Code 3.023364
Class of device V or VI*
Contribution to the environmental heating seasonal energy efficiency 3% or 4%*
 
* as standard
System controller       Code 3.021522
Class of device VI* or VIII
Contribution to the environmental heating seasonal energy efficiency 4%* or 5%
 
* as standard
Temperature/humidity active sensor kit       Code 3.021524

To be used with radiant systems that also work in cooling mode.

Class of device V or VI*
Contribution to the environmental heating seasonal energy efficiency 3%* or 4%*

* as standard

Room hygrostat       Code 3.023302

To be used with radiant systems that also work in cooling mode.

System controller expansion kit       Code 3.021547

 

 

External probe (for single installation)      Code 3.015266

To be used when external probe as standard in outdoor unit is not correctly exposed.


Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%

* default settings

CRONO 7 (weekly digital chronothermostat)       Code 3.021622

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)       Code 3.021624

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

2 relays board kit       Code 3.026302

To be installed for the deumidifiers management without in absence of system manager kit.

Dedicated to MAGIS PRO ErP and MAGIS COMBO.

 

 

Solar probe kit       Code 3.021452
For VICTRIX TT SERIES, VICTRIX EXA, VICTRIX TERA, VICTRIX TERA VIP,  NIKE ECO 24, MAIOR EOLO and MAGIS COMBO
 
Storage tank NTC probe       Code 3.019375

Allows to check the DHW temperature of a commercial Storage Tank Unit with the Immergas boiler <35 kW.
Provided as per standard on all Storage Tank Units in the catalogue.

Flue systems
Options
HYDRO IN 200     Code 3.029841
Wall and ceiling built-in hydronic fancoil
 
 
 
HYDRO IN 600    Code 3.029843
Wall and ceiling built-in hydronic fancoil
 
 
 
ZENITAIR MONO     Code 3.030601
Decentralised mechanical ventilation unit, easy to install, with alternate flow and heat recovery core.
Multifunction remote controller, with LCD display to visualise the status of the unit supplied as standard.
 
 
 
 
Distribution manifold kit for 1 direct and 2 mixed temperature zones      Code 3.021527
The kit includes an expansion for the system controller for each zone, a 24 Vac transformer and an NTC probe for each mixed delivery.
Wall-hung or recessed installation. Low consumption pumps.
Connection kit for R410A circuit      Code 3.026089
Per connessioni raccordi gas unità esterna MAGIS COMBO/PLUS e MAGIS PRO ErP dalla parete in cui è installata l'unità interna.
HYDRO FS 200     Code 3.028500
Floor standing hydronic fancoil 
 
 
 
External cover kit with acoustical insulation for ZENITAIR-MONO    Code 3.030636
Anti-insect net and anti-wind in pre-painted steel, alternative to the one available with ZENITAIR-MONO.
 
 
 
 
Connection kit for R410A circuit      Code 3.026089
Per connessioni raccordi gas unità esterna MAGIS COMBO/PLUS e MAGIS PRO ErP dalla parete in cui è installata l'unità interna.
HYDRO 3     Code 3.027918
Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
Connection kit for R410A circuit      Code 3.026089
Per connessioni raccordi gas unità esterna MAGIS COMBO/PLUS e MAGIS PRO ErP dalla parete in cui è installata l'unità interna.
HYDRO IN 400     Code 3.029842
Wall and ceiling built-in hydronic fancoil
 
 
 
HYDRO IN 1000     Code 3.029845
Wall and ceiling built-in hydronic fancoil
 
 
 
HYDRO IN 800     Code 3.029844
Wall and ceiling built-in hydronic fancoil
 
 
 
Connection kit for R410A circuit      Code 3.026089
Per connessioni raccordi gas unità esterna MAGIS COMBO/PLUS e MAGIS PRO ErP dalla parete in cui è installata l'unità interna.
HYDRO 4     Code 3.027919
Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
HYDRO FS 400     Code 3.028501
Floor standing hydronic fancoil
 
Distribution manifold for 1 direct and 1 mixed temperature zones     Code 3.026301

Kit to be used without system manager controller. Dedicated to MAGIS PRO V2 and MAGIS COMBO.

Distribution manifold kit for 2 mixed temperature zones     Code 3.021528
The kit includes an expansion for the system controller for each zone, a 24 Vac transformer and an NTC probe for each delivery.
Wall-hung or recessed installation. Low consumption pumps.
HYDRO FS 600     Code 3.028502
Floor standing hydronic fancoil 
 
 
Dehumidifier kit     Code 3.021529
Only for recessed installation with codes 3.022146 and 3.022147

 

HYDRO FS 800     Code 3.028503
Floor standing hydronic fancoil 
 
 
Dehumidifier back frame kit     Code 3.022146
HYDRO FS 1000     Code 3.028505
Floor standing hydronic fancoil 
 
Dehumidifier front grille kit     Code 3.022147
Bracket kit for wall mounting inertial storage tank for MAGIS COMBO     Code 3.027290
Bracket kit for wall mounting inertial storage tank 75 litres code 3.027288.
 
Vertical inertial storage tank 75 litre for MAGIS COMBO     Code 3.027288
For solutions with hybrid heat pumps MAGIS COMBO.
Wall-hung (with bracket option kit) or floor-standing installation.
Anti-scale kit for VICTRIX SUPERIOR ErP, MAIOR TT ErP, TT ErP, TT, EXA ErP, TERA, TERA VIP and MAGIS COMBO       Code 3.017323

For VICTRIX SUPERIOR ErP, MAIOR TT ErP, TT ErP, TT, EXA ErP, TERA, TERA VIP and MAGIS COMBO.

Thermoregulation
Flue systems
Options
Related products
MAGIS COMBO 8 PLUS
Air-water inverter mono-phase hybrid heat pump

OPEN PRODUCT

 
CONTACT US
 
 
 
CUSTOMER CARE
 
QUALITY IN SERVICES
MADE IN ITALY
50 years of experience
OVER 6 MILLION BOILERS INSTALLED