IT / EN
Skip to Content
MAGIS COMBO 9 PLUS V2
Code (ref. N.G.) 3.030619
Heating output kW 9,00
Cooling output kW 8,70
Indoor Unit (HxWxD) mm 787 x 440 x 400
Outdoor Unit (HxWxD) mm 1010 x 940 x 384
Refrigerant gas R32
COP 4,81
EER 4,12
Outdoor Unit weight (kg) 74,0
Indoor unit weight (kg) 55,8

A++

A+++

Split air to water, inverter-driven monophase hybrid heat pump system, consisting of outdoor heat pump unit and indoor hydronic and condensing unit. 

The new MAGIS COMBO V2 hybrid heat pumps are appliances designed to use outside air as a partially renewable heat source by transferring its thermal energy content to the central heating system. MAGIS COMBO V2 is the hybrid heat pump that heats, cools and produces hot water with an internal condensing unit designed to meet the highest demands, its heating temperature can reach up to 80 °C.

For installation it's necessary the degree of training required to professional people (that have to be in possess of F-GAS certification) involved in the installation and their mutual connection by means of the gas circuit. The inverter driven control allows a very fine power output modulation control, together with reduction of the power input, succeeding in high level performances for more comfortable indoor climatic conditions.

MAGIS COMBO V2 are domestic-purpose-suit systems, and they are the ideal solution in new, high energy rating buildings, even when located in extremely cold areas, with very low outdoor-winter-temperatures.

The very compact external unit (smaller compared to the most diffused hydronic heat pump models), installable both on balcony and fully outdoor, allows to MAGIS COMBO V2 enhanced positional flexibility together with a minimal aestethic effect on the overall style.

MAGIS COMBO V2 is ideal for combination with photovoltaic systems.

Noiseless
Easy installation
Heating and cooling
Thermoregulation
Remote Control Panel       Code 3.030863
For MAGIS PRO V2 and MAGIS COMBO V2
 
Modulating remote control only for V2 versions

Temperature control class V* or VI
Contribution to seasonal space heating energy efficiency
3%* or 4%
 
* default settings
Temperature/humidity active sensor kit for MAGIS PRO V2 and MAGIS COMBO V2      Code 3.030992

To be used with radiant systems that also work in
cooling mode only for MAGIS PRO V2 and MAGIS COMBO V2 versions.


Temperature control class V or VI*
Contribution to seasonal space heating energy efficiency
3% or 4%*

* default settings

Room hygrostat       Code 3.023302

To be used with radiant systems that also work in cooling mode.

External probe (for single installation)      Code 3.015266

To be used when external probe as standard in outdoor unit is not correctly exposed.


Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%

* default settings

CRONO 7 (weekly digital chronothermostat)       Code 3.021622

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)       Code 3.021624

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

2 relays board kit       Code 3.026302

To be installed for the deumidifiers management without in absence of system manager kit.

Dedicated to MAGIS PRO V2 and MAGIS COMBO V2

 

 

Storage tank NTC probe       Code 3.019375

Allows to check the DHW temperature of a commercial Storage Tank Unit with the Immergas boiler <35 kW.
Provided as per standard on all Storage Tank Units in the catalogue.

DOMINUS interface kit       Code 3.026273
To control heat pumps, system or gas boilers and display operation data on your tablet, smartphone and portable PC.
Using DOMINUS interface kit, installed before your modem/router wireless (not supplied by Immergas), you
can communicate with the heat pump’s circuit board from any location.
Relay board kit       Code 3.015350
Allows interface between zone valves and CAR V2 or SUPER CAR, to send an alarm signal, to manage external pump etc.
 
To be installed inside internal unit both in MAGIS COMBO V2 and MAGIS PRO V2
Low temperature safety kit      Code 3.019229

For generators settled up with low temperature

Flue systems
Options
HYDRO IN 200     Code 3.029841
Wall and ceiling built-in hydronic fancoil
 
 
 
HYDRO IN 600    Code 3.029843
Wall and ceiling built-in hydronic fancoil
 
 
 
ZENITAIR MONO     Code 3.030601
Decentralised mechanical ventilation unit, easy to install, with alternate flow and heat recovery core.
Multifunction remote controller, with LCD display to visualise the status of the unit supplied as standard.
 
 
 
 
HYDRO FS 200     Code 3.028500
Floor standing hydronic fancoil 
 
 
 
External cover kit with acoustical insulation for ZENITAIR-MONO    Code 3.030636
Anti-insect net and anti-wind in pre-painted steel, alternative to the one available with ZENITAIR-MONO.
 
 
 
 
HYDRO 3     Code 3.027918
Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
HYDRO IN 400     Code 3.029842
Wall and ceiling built-in hydronic fancoil
 
 
 
HYDRO IN 1000     Code 3.029845
Wall and ceiling built-in hydronic fancoil
 
 
 
HYDRO IN 800     Code 3.029844
Wall and ceiling built-in hydronic fancoil
 
 
 
Connection kit for R32 circuit for MAGIS PRO V2 and MAGIS COMBO V2     Code 3.030883
for an easy connection of the refrigerant circuit, even
in the case of pipes coming out from the wall on the
internal unit 
HYDRO 4     Code 3.027919
Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
HYDRO FS 400     Code 3.028501
Floor standing hydronic fancoil
 
Distribution manifold for 1 direct and 1 mixed temperature zones     Code 3.026301

Kit to be used without system manager controller. Dedicated to MAGIS PRO V2 and MAGIS COMBO V2

HYDRO FS 600     Code 3.028502
Floor standing hydronic fancoil 
 
 
Dehumidifier kit     Code 3.021529
Only for recessed installation with codes 3.022146 and 3.022147

 

HYDRO FS 800     Code 3.028503
Floor standing hydronic fancoil 
 
 
Dehumidifier back frame kit     Code 3.022146
HYDRO FS 1000     Code 3.028505
Floor standing hydronic fancoil 
 
Dehumidifier front grille kit     Code 3.022147
Wall mounting brackets for AUDAX 6/8 and external units of MAGIS COMBO V2 and MAGIS PRO V2  Code 3.022154
Bracket kit for wall mounting inertial storage tank for MAGIS COMBO V2     Code 3.027290
Bracket kit for wall mounting inertial storage tank 75 litres code 3.027288.
 
Vertical inertial storage tank 75 litre for MAGIS COMBO V2   Code 3.027288
For solutions with hybrid heat pumps MAGIS COMBO V2.
Wall-hung (with bracket option kit) or floor-standing installation.
Anti freeze protection kit -15 °C        Code 3.017324

Anti freeze protection kit -15 °C  
For TT versions, EXA, TERA, OMNIA, VICTRIX ZEUS SUPERIOR ErP, VICTRIX ZEUS, MAGIS PRO V2 and MAGIS COMBO V2.

Condensate antifreeze heating cable kit       Code 3.027385

for external unit

Anti-scale kit for VICTRIX SUPERIOR ErP, MAIOR TT ErP, TT ErP, TT, EXA ErP, TERA, TERA VIP and MAGIS COMBO V2      Code 3.017323

For VICTRIX SUPERIOR ErP, MAIOR TT ErP, TT ErP, TT, EXA ErP, TERA, TERA VIP and MAGIS COMBO.

Condensate discharge pump kit      Code 3.026374

For wall-hung boilers: compact condensate drain pump kit.

3-way valve kit       Code 3.020632
Thermoregulation
Flue systems
Options
 
CONTACT US
 
 
 
CUSTOMER CARE
 
QUALITY IN SERVICES
MADE IN ITALY
57 years of experience
OVER 7 MILLION BOILERS INSTALLED