IT / EN
Skip to Content
VICTRIX SUPERIOR 35 PLUS
Wall-hung combi condensing boiler with “Aqua Celeris” and magnetic cyclone filter
Code 3.033011
Heat output kW 32,0
Dimensions (HxWxD) mm 775 x 440 x 389
Type heating only
Modulating heat output 7 - 100%

A

A

Single product code to work with methane, LPG or 20% hydrogen blend (gas adaptive technology)

• 94% seasonal efficiency to reach a higher energy classification (A+) in combination with Modulating Remote Controls (ie. SMARTECH PLUS, CAR V2 or CRD PLUS).

• NOx class 6

• Possibility of single installation or in cascade (up to 8 appliances, thanks to cascade option kit cod. 3.020355)

• Connection to Immerstor range by means option kit 3.022848

• 3 star marking sanitary comfort

•  Adjustable system by-pass

• Standard frost protection up to -3 °C

• Connection kit as standard

• Magnetic cyclone filter kit as standard

• The standard clapet allows the combination with multiple exhaust systems under positive pressure

• The hi-tech electronics provides numerous new functions such as the possibility to manage 3 zones directly from the boiler control panel or the convenience of setting 4 comfort time bands and 4 calendars

 

3 star marking sanitary comfort
Hot water quick erogation
Modulating pump
Thermoregulation
Electrical box cover plate kit for SMARTECH PLUS       Code 3.031013

It allows the covering of the wall hole for electrical boxes type 503.

SMARTECH PLUS - SMART remote control       Code 3.030909

Hi-tech smart wireless remote control with Bluetooth technology

The kit includes:
• Chronothermostat (to be placed where you want to adjust the temperature)
• Gateway (to be connected to the boiler or to the internet network at home - power supply 230 V)
• Wall fixing base (with leveling bubble integrated)
• Table stand
• 2 power batteries (as standard)
• Functioning room temperature: 0 - +40 °C
• Protection rating IP 20


Temperature control class: V* or VI
Contribution to seasonal space heating energy efficiency 3%* or 4%

 

*default settings.

Expansion kit for SMARTECH PLUS       Code 3.030911

For controlling the temperature in several areas of the house (example living and sleeping areas).

The kit includes: additional SMART thermostat and wi-fi relay (in this case the wi-fi network is required).

 

CARV2 (weekly chronothermostat and modulating remote control)       Code 3.021395

Class of device V* or VI

Contribution to the environmental heating seasonal energy efficiency 3%* or 4%

*as standard

CRONO 7 (weekly digital chronothermostat)       Code 3.021622

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)       Code 3.021624

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

External probe       Code 3.014083
Allows at the boiler to functioning at a variable temperature according to the climatic conditions.
Available for all models, except MYTHOS HP, NIKE/EOLO STAR and NIKE/EOLO MYTHOS.
 

Class of device II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4% or 3,5%

* as standard

GSM telephonic control       Code 3.017182

For buildings not equipped with telephone network. Available for all Immergas models.

Telephonic control       Code 3.013305

For buildings equipped with telephone network. Available for all Immergas models.

Zone control unit V2 kit       Code 3.030912

Control unit for external circulators/zone valves to manage 3 zones (2 mixed and 1 direct).

Wireless room sensor kit       Code 3.030906

Ideal for reading the room temperature of second or third zone.

To be matched to sensor receiver code 3.030908.

Product class V* or VI

Seasonal energy efficiency value 3%* or 4%

*as standard

 

System delivery probe kit   Code 3.030913
To be positioned after the heating system manifold.
DOMINUS interface kit       Code 3.026273
To control heat pumps, system or gas boilers and display operation data by means DOMINUS App.
Installed before your modem/router wireless (not supplied by Immergas), you can communicate with the heat pump’s circuit board from any location.
Wireless room sensors receiver kit      Code 3.030908
The kit includes 1 room sensor and one receiver for the dialogue between boiler and room sensor.
 

Product class V* or VI

Seasonal energy efficiency value 3%* or 4%

*as standard

 
VICTRIX SUPERIOR 32 PLUS cascade kit       Code 3.020355

To match VICTRIX SUPERIOR 35 PLUS in cascade
Electric interface Gas boiler-Cascade and zones regulator kit; it is necessary one interface each gas boiler.

Low temperature safety thermostat kit    Code 3.019229

For generators settled up with low temperature

Flue systems
Horizontal concentric complete kit Ø 60/100 with swivel terminal       Code 3.024267
Max lenght 9,9 m.
For condensing boiler < 35 kW except HP models.

 

 

Concentric horizontal complete kit Ø 60/100       Code 3.012000

Max lenght 12,9 m.
For condensing boiler < 35 kW.

Horizontal concentric complete kit Ø 60/100 Short       Code 3.024598

Max lenght 11,9 m.
For condensing boiler < 35 kW.

Concentric vertical complete kit Ø 60/100 (red ocher colour)       Code 3.016833

for condensing boilers < 35 kW.

Twin pipes complete kit Ø 80/80       Code 3.012002

For condensing boiler < 35 kW.

Terminal vertical outlet kit Ø 80       Code 3.015256

For condensing boiler < 35 kW.

Anti-wind vertical terminal kit Ø 80       Code 3.021721

For condensign boiler < 35 kW.

Clapet kit for for collective flue systems operating under positive pressure      Code 3.031599

for VICTRIX ZEUS SUPERIOR and VICTRIX SUPERIOR

Exhaust manifold kit Ø160   Code 3.032852

For indoor installation of 2 VICTRIX SUPERIOR 35 PLUS in cascade

Additional exhaust manifold kit Ø 160       Code 3.032853

For indoor installation of VICTRIX SUPERIOR 35 PLUS in cascade

Cover kit for VICTRIX SUPERIOR    Code 3.032166

For partially protected area installation
 

Options
DIM 3 ZONES ErP       Code 3.025608
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 3 low consumption pumps and electronic board.
DIM H-LT ErP       Code 3.025609
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 2 low consumption pumps, 1 mixing valve and electronic board.
DIM H-2LT ErP       Code 3.025610

Kit for mixed systems with 2 low temperature zones and 1 high temperature zone.
High energetic efficiency thanks to class A pumps. Hydraulic manifold, 3 low consumption pumps, 2 mixing valves and electronic board.

DIM BASIC ErP      Code. 3.025606
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
Hydraulic manifold and 1 low-consumption pump.
DIM 2 ZONES ErP       Code 3.025607
Multisystem distribution manifolds for the management of zone systems and systems requiring great water flows.
Hydraulic manifold, 2 low-consumption pumps and electronic board.
Bracket kit for Free-Standing frame    Code 3.032171
For VICTRIX SUPERIOR 35 PLUS
Anti freeze protection kit -15 °C        Code 3.017324

Anti freeze protection kit -15 °C  
For TT versions, VICTRIX SUPERIOR/PLUS, VICTRIX ZEUS, VICTRIX EXA, TERA VIP, VICTRIX TERA/PLUS, OMNIA, MAGIS PRO V2 and MAGIS COMBO V2.

2 litres additional expansion vessel for VICTRIX SUPERIOR   Code 3.032168

For VICTRIX SUPERIOR.

Condensate neutralizer kit   Code 3.019857
Necessary to neutralize the acidity of the condensation. Inclusive of granulate.
Shut off knobs       Code 3.5324

For wall-hung outdoor boilers.

 

 

Shut off knobs with filter       Code 3.015854

For wall-hung boilers and MAGIS VICTRIX ErP.

All-purpose connection kit for wall-hung combi boilers       Code 3.011667

For wall-hung combi boilers and also for wall-hung with built-in storage tank.

Anti-scale kit for VICTRIX SUPERIOR, MAIOR TT, TT ErP, TT, EXA ErP, TERA, TERA VIP and MAGIS COMBO V2      Code 3.017323

For VICTRIX SUPERIOR, MAIOR TT ErP, TT ErP, TT, EXA ErP, TERA, TERA VIP and MAGIS COMBO V2.

Bottom cover kit for VICTRIX SUPERIOR     Code 3.032167

for VICTRIX SUPERIOR 

Condensate discharge pump kit      Code 3.026374

For wall-hung boilers: compact condensate drain pump kit.

Hydraulic manifold for 2 boilers in cascade   Code 3.032169

For 2 VICTRIX SUPERIOR 35 PLUS in cascade

2,7 bar safety valve included

Thermoregulation
Flue systems
Options
Related products
UB INOX SOLAR 200 V2
Inox Storage Tank Unit for production of domestic hot water and built-in solar circuit

OPEN PRODUCT

UB INOX 200 V2
Inox Storage Tank Unit for production of domestic hot water

OPEN PRODUCT

 
CONTACT US
 
 
 