MAGIS HERCULES PRO 6

Spilt type reversible air-to-water inverter driven heat pump system composed by an external unit and a floor standing internal unit
The customer service provides
prompt answers within 24 hours.
3 star marking sanitary comfort
Ideal for new buildings
Heating and cooling

Technical data MAGIS HERCULES PRO 6

Code 3.030429
C.H. Energy class at 55 °C A++
D.H.W. Energy class - Stated load profile A / L
Heating output kW 6,00
Cooling output kW 6,50
Hydronic Unit (HxWxD) mm 1970 x 650 x 913
Condensing Unit (HxWxD) mm 638 x 880 x 361
Refrigerant gas R32
COP 4,92
EER 4,42
External unit empty appliance weight (kg) 46,5
Internal unit empty appliance weight (kg) 211

Technical data MAGIS HERCULES PRO 6

Code 3.030429
C.H. Energy class at 55 °C A++
D.H.W. Energy class - Stated load profile A / L
Heating output kW 6,00
Cooling output kW 6,50
Hydronic Unit (HxWxD) mm 1970 x 650 x 913
Condensing Unit (HxWxD) mm 638 x 880 x 361
Refrigerant gas R32
COP 4,92
EER 4,42
External unit empty appliance weight (kg) 46,5
Internal unit empty appliance weight (kg) 211

Gallery

ADVANCED SOLUTIONS FOR NEW HOUSES
MAGIS HERCULES PRO offers a wide range of models: single-phase with R32 refrigerant gas of 4, 6, 9 kW
and single-phase or three-phase with R410A refrigerant gas of 12, 14, 16 kW.
They are highly efficient appliances, perfect for obtaining the highest energy classes in new residential
buildings of large dimensions even where external temperatures can be particularly freezing.
"ALL IN ONE" TO MAKE INSTALLATION EASIER
MAGIS HERCULES PRO "all-in-one" appliances are easy to assemble because they join, inside the single
casing, the 235-liter DHWstorage tank and the ability to manage systems up to 3 zones, all with a complete
range of accessories. The suffix "PRO" refers to the requirement for installation by professionals, with
F-GAS certification for the refrigeration connections between the 2 units.
PROTECTED FROM FROST
The water circuit is completely protected from frost because it is located inside the internal unit:
solution particularly suitable in cold climatic areas.
MAXIMIZE YOUR SAVINGS WITH PHOTOVOLTAIC SYSTEMS
MAGIS HERCULES PRO combines in the most effective way with photovoltaic systems and allows to obtain
domestic hot water, heating and cooling with the free energy of the sun.

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

...

DOMINUS interface kit   Cod.3.026273

To control heat pumps, system or gas boilers and display operation data by means DOMINUS App.
Installed before your modem/router wireless (not supplied by Immergas), you can communicate with the heat pump’s circuit board from any location.
...

External probe   Cod.3.015266

To be used when external probe as standard in outdoor unit is not correctly exposed.


Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%

* default settings

...

Low temperature safety thermostat kit   Cod.3.019229

For generators settled up with low temperature

...

Mod-bus temperature and humidity sensor   Cod.3.030992

To be used with radiant systems that also work in cooling mode 

Temperature control class V or VI*
Contribution to seasonal space heating energy efficiency
3% or 4%*

* default settings

...

Remote Control Panel   Cod.3.030863

Modulating chronotermostat, remote control with temperature/humidity sensor

Temperature control class V* or VI
Contribution to seasonal space heating energy efficiency 3%* or 4%
 
* default settings
...

Room hygrostat   Cod.3.023302

To be used with radiant systems that also work in cooling mode.

...

System delivery probe kit   Cod.3.030913

To be positioned after the heating system manifold.
...

2,3 kW - DHW integration electric heater kit for MAGIS HERCULES PRO   Cod.3.030862

 

 

...

2nd mixed zone kit for MAGIS HERCULES PRO 4-6-9   Cod.3.030855

For MAGIS HERCULES PRO 4/6/9.
Composed by: 1 low consumption pump, mixing valve and
connection pipes.

...

3 kW - Integration electric heater kit   Cod.3.030899

For MAGIS HERCULES PRO and MAGIS HERCULES PRO MINI.

 

...

3-way valve kit   Cod.3.020632

...

3rd mixed zone kit for MAGIS HERCULES PRO 4-6-9   Cod.3.030856

For MAGIS HERCULES PRO 4/6/9.
Composed by: 1 low consumption pump, 1 mixing valve,
connection pipes and expansion.

...

Connection kit R32 gas refrigerant circuit   Cod.3.031505

for MAGIS HERCULES PRO 4-6-9 

Allow an easy connection of the refrigerant
circuit in the case of pipes coming out from the indoor unit
rear wall.

...

Dehumidifier back frame kit   Cod.3.022146

...

Dehumidifier front grille kit   Cod.3.022147

...

Dehumidifier kit   Cod.3.021529

Only for recessed installation with codes 3.022146 and 3.022147

 

...

Double electronic anode kit   Cod.3.025003

Double electronic anode kit for OMNISTOR, INOXSTOR V2, MAGIS HERCULES PRO and MAGIS HERCULES PRO MINI
 
 
...

External cover kit with acoustical insulation for ZENITAIR-MONO   Cod.3.030636

Anti-insect net and anti-wind in pre-painted steel, alternative to the one available with ZENITAIR-MONO.
 
 
 
 
...

HYDRO 3 V2   Cod.3.033625

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO IN 200   Cod.3.029841

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO 4 V2   Cod.3.033626

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO FS 200   Cod.3.028500

Floor standing hydronic fancoil 
 
 
 
...

HYDRO FS 400   Cod.3.028501

Floor standing hydronic fancoil
 
...

HYDRO FS 600   Cod.3.028502

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 800   Cod.3.028503

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 1000   Cod.3.028505

Floor standing hydronic fancoil 
 
...

HYDRO IN 400   Cod.3.029842

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 600   Cod.3.029843

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 800   Cod.3.029844

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 1000   Cod.3.029845

Wall and ceiling built-in hydronic fancoil
 
 
 
...

Recirculation kit with pump   Cod.3.030858

To be installed inside the MAGIS HERCULES PRO internal unit casing 

...

Shut off knobs 1   Cod.3.030860

Shut off knobs, 1" connections (for zones 2 and 3 only).

...

Shut off knobs with filters for MAGIS HERCULES PRO   Cod.3.030861

Shut off knobs with filters

1" connections (for zones 2 and 3, only); standard for zone 1.

...

Solar kit for MAGIS HERCULES PRO   Cod.3.030857

For MAGIS HERCULES PRO.

Composed by: plate heat exchanger, single solar pump
station (with low consumption circulation pump), solar
central unit, connection pipes,18 litre solar expansion vessel,
temperature probes (for collectors and storage tank).
N.B.: For solar panel and other solar accessories see the
solar catalogue.

...

Wall mounting brackets for external unit   Cod.3.034758

For outdoor unit of MAGIS COMBO 4-6-9 V2/ 4-6-9 PLUS V2, MAGIS COMBO 12-14-16 V2/ 12-14-16 PLUS V2, TRIO PACK 4-6-9, TRIO HYDRO 5-8-12, MAGIS HERCULES PRO 4-6-9-12-14-16, MAGIS PRO 4-6-9 V2 /12-14-16 V2, MAGIS HERCULES PRO MINI 6-9/6-9 EU.

...

ZENITAIR MONO   Cod.3.030601

Decentralised mechanical ventilation unit, easy to install, with alternate flow and heat recovery core.
Multifunction remote controller, with LCD display to visualise the status of the unit supplied as standard.
 
 
 
 

ADVANCED SOLUTIONS FOR NEW HOUSES
MAGIS HERCULES PRO offers a wide range of models: single-phase with R32 refrigerant gas of 4, 6, 9 kW
and single-phase or three-phase with R410A refrigerant gas of 12, 14, 16 kW.
They are highly efficient appliances, perfect for obtaining the highest energy classes in new residential
buildings of large dimensions even where external temperatures can be particularly freezing.
"ALL IN ONE" TO MAKE INSTALLATION EASIER
MAGIS HERCULES PRO "all-in-one" appliances are easy to assemble because they join, inside the single
casing, the 235-liter DHWstorage tank and the ability to manage systems up to 3 zones, all with a complete
range of accessories. The suffix "PRO" refers to the requirement for installation by professionals, with
F-GAS certification for the refrigeration connections between the 2 units.
PROTECTED FROM FROST
The water circuit is completely protected from frost because it is located inside the internal unit:
solution particularly suitable in cold climatic areas.
MAXIMIZE YOUR SAVINGS WITH PHOTOVOLTAIC SYSTEMS
MAGIS HERCULES PRO combines in the most effective way with photovoltaic systems and allows to obtain
domestic hot water, heating and cooling with the free energy of the sun.

...

CRONO 7 (weekly digital chronothermostat)   Cod.3.021622

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating seasonal energy efficiency 2%* or 3,5%

* default settings

...

CRONO 7 WIRELESS (wireless weekly digital chronothermostat)   Cod.3.021624

ON/OFF room thermostat.

 

Class of device IV* or VII

Contribution to the environmental heating energy efficiency 2%* or 3,5%

* default settings

...

DOMINUS interface kit   Cod.3.026273

To control heat pumps, system or gas boilers and display operation data by means DOMINUS App.
Installed before your modem/router wireless (not supplied by Immergas), you can communicate with the heat pump’s circuit board from any location.
...

External probe   Cod.3.015266

To be used when external probe as standard in outdoor unit is not correctly exposed.


Temperature control class II*, VI or VII
Contribution to seasonal space heating energy efficiency 2%*, 4 or 3,5%

* default settings

...

Low temperature safety thermostat kit   Cod.3.019229

For generators settled up with low temperature

...

Mod-bus temperature and humidity sensor   Cod.3.030992

To be used with radiant systems that also work in cooling mode 

Temperature control class V or VI*
Contribution to seasonal space heating energy efficiency
3% or 4%*

* default settings

...

Remote Control Panel   Cod.3.030863

Modulating chronotermostat, remote control with temperature/humidity sensor

Temperature control class V* or VI
Contribution to seasonal space heating energy efficiency 3%* or 4%
 
* default settings
...

Room hygrostat   Cod.3.023302

To be used with radiant systems that also work in cooling mode.

...

System delivery probe kit   Cod.3.030913

To be positioned after the heating system manifold.
...

2,3 kW - DHW integration electric heater kit for MAGIS HERCULES PRO   Cod.3.030862

 

 

...

2nd mixed zone kit for MAGIS HERCULES PRO 4-6-9   Cod.3.030855

For MAGIS HERCULES PRO 4/6/9.
Composed by: 1 low consumption pump, mixing valve and
connection pipes.

...

3 kW - Integration electric heater kit   Cod.3.030899

For MAGIS HERCULES PRO and MAGIS HERCULES PRO MINI.

 

...

3-way valve kit   Cod.3.020632

...

3rd mixed zone kit for MAGIS HERCULES PRO 4-6-9   Cod.3.030856

For MAGIS HERCULES PRO 4/6/9.
Composed by: 1 low consumption pump, 1 mixing valve,
connection pipes and expansion.

...

Connection kit R32 gas refrigerant circuit   Cod.3.031505

for MAGIS HERCULES PRO 4-6-9 

Allow an easy connection of the refrigerant
circuit in the case of pipes coming out from the indoor unit
rear wall.

...

Dehumidifier back frame kit   Cod.3.022146

...

Dehumidifier front grille kit   Cod.3.022147

...

Dehumidifier kit   Cod.3.021529

Only for recessed installation with codes 3.022146 and 3.022147

 

...

Double electronic anode kit   Cod.3.025003

Double electronic anode kit for OMNISTOR, INOXSTOR V2, MAGIS HERCULES PRO and MAGIS HERCULES PRO MINI
 
 
...

External cover kit with acoustical insulation for ZENITAIR-MONO   Cod.3.030636

Anti-insect net and anti-wind in pre-painted steel, alternative to the one available with ZENITAIR-MONO.
 
 
 
 
...

HYDRO 3 V2   Cod.3.033625

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO IN 200   Cod.3.029841

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO 4 V2   Cod.3.033626

Wall-hung hydronic fancoil with LCD remote control and 3-way valve with micro switch on-off, as standard 
...

HYDRO FS 200   Cod.3.028500

Floor standing hydronic fancoil 
 
 
 
...

HYDRO FS 400   Cod.3.028501

Floor standing hydronic fancoil
 
...

HYDRO FS 600   Cod.3.028502

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 800   Cod.3.028503

Floor standing hydronic fancoil 
 
 
...

HYDRO FS 1000   Cod.3.028505

Floor standing hydronic fancoil 
 
...

HYDRO IN 400   Cod.3.029842

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 600   Cod.3.029843

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 800   Cod.3.029844

Wall and ceiling built-in hydronic fancoil
 
 
 
...

HYDRO IN 1000   Cod.3.029845

Wall and ceiling built-in hydronic fancoil
 
 
 
...

Recirculation kit with pump   Cod.3.030858

To be installed inside the MAGIS HERCULES PRO internal unit casing 

...

Shut off knobs 1   Cod.3.030860

Shut off knobs, 1" connections (for zones 2 and 3 only).

...

Shut off knobs with filters for MAGIS HERCULES PRO   Cod.3.030861

Shut off knobs with filters

1" connections (for zones 2 and 3, only); standard for zone 1.

...

Solar kit for MAGIS HERCULES PRO   Cod.3.030857

For MAGIS HERCULES PRO.

Composed by: plate heat exchanger, single solar pump
station (with low consumption circulation pump), solar
central unit, connection pipes,18 litre solar expansion vessel,
temperature probes (for collectors and storage tank).
N.B.: For solar panel and other solar accessories see the
solar catalogue.

...

Wall mounting brackets for external unit   Cod.3.034758

For outdoor unit of MAGIS COMBO 4-6-9 V2/ 4-6-9 PLUS V2, MAGIS COMBO 12-14-16 V2/ 12-14-16 PLUS V2, TRIO PACK 4-6-9, TRIO HYDRO 5-8-12, MAGIS HERCULES PRO 4-6-9-12-14-16, MAGIS PRO 4-6-9 V2 /12-14-16 V2, MAGIS HERCULES PRO MINI 6-9/6-9 EU.

...

ZENITAIR MONO   Cod.3.030601

Decentralised mechanical ventilation unit, easy to install, with alternate flow and heat recovery core.
Multifunction remote controller, with LCD display to visualise the status of the unit supplied as standard.
 
 
 
 

Related products

MAGIS HERCULES PRO 9
Split type mono-phase heat pump with 235 litres DHW
MAGIS HERCULES PRO 4
Split type mono-phase heat pump with 235 litres DHW
MAGIS HERCULES PRO MINI 6

Split type mono-phase heat pump with 180 litres DHW

MAGIS HERCULES PRO MINI 9

Split type mono-phase heat pump with 180 litres DHW